¡@
 
Language¡G
¤½¥q²¤¶ ²£«~¤¶²Ð ³Ì·s®ø®§ ³Ì·s²£«~ «P¾P²£«~ ¼tµP¤¶²Ð ÀɮפU¸ü ³sµ¸§Ú­Ì ¦^­º­¶



¹q¸Ñ¦¡¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡½¤«p­p--¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
½¤«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h­«Âì«p«×¤Î¹q¦ì®t´ú©w²Õ¦X-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h¼hÂì¹qÁá­@»G»k´ú©w¸Ë¸m-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡¹qÁá«p«×´ú©w¾¹¥Î ¹q¸Ñ²G-¤¤¥¡»s§@©Ò
¶W­µªi²M¬~¾÷-¤¤¥¡»s§@©Ò
µL¹q¸ÑÂì¹qÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q·½¸Ë¸m/¾ã¬y¾¹-¤¤¥¡»s§@©Ò
¥ú¿A¾¯¦Û°Ê²K¥[¸Ë¸m-¤¤¥¡»s§@©Ò
PH/ORP±±»s¾¹-¤¤¥¡»s§@©Ò
¤T»ù»ÌÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q¸Ñ¤òÃä¥h°£¸Ë¸m-¤¤¥¡»s§@©Ò
ºÏ©Ê/«DºÏ©Ê/¨â¥Î«¬½¤«p­p
¶W­µªi¦h¼h½¤«p­p
X-ray¿Ã¥úÁá¼h´ú«p»ö
ÆQ¤ô¼QÃú¸ÕÅç¾÷
¥iµ{¦¡ùÚ·ÅùÚÀã¸ÕÅç¾÷
ºë±K¯M½c
Thickness Tester-Chuo Seisakusho.,LTD.
ùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù
¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u
¦Û°Êºw©w»ö-¤éªFºë¤u
Á`²¸¤ÀªR»ö-¤éªFºë¤u
Á`´â¤ÀªR»ö-¤éªFºë¤u
Á`´á¤ÀªR»ö-¤éªFºë¤u
¦Û°Ê¼Ë«~¿U¿N¸Ë¸m-¤éªFºë¤u
Á`¦³¾÷³¿¯À¤ÀªR»ö-¤éªFºë¤u
°ª/§Cªý§Ü²v­p-¤éªFºë¤u
¿n¤À²y¦¡¿B«×­p-¤éªFºë¤u
¤ô¥÷­p¥Î¹q¸Ñ²G¤Î¸Õ¾¯-¤éªFºë¤u
Á`¦³¾÷ºÒ¤ÀªR»ö-¤éªFºë¤u
³¿¯À¿O¤ô¥÷­p
¼ö¤ÀªR¨t¦C
¼ö¶Ç¾É«Y¼Æ¨t¦C
  ¤ÀÃþ >>  ¼ö¤ÀªR¨t¦C >> 
    ¦PÃþ°Ó«~ >> 
NEXTA DSC 600  NEXTA DSC¼ö¥Ü®t±½ºË¥d¶q­p(NEXTA DSC 600) ¤H®ð«ü¼Æ 1512
«¬¸¹¡GNEXTA DSC 600
¤¤¤å¦WºÙ¡GNEXTA DSC¼ö¥Ü®t±½ºË¥d¶q­p(NEXTA DSC 600)
­^¤å¦WºÙ¡GDifferential Scanning Calorimeter (Heat Flux DSC) NEXTA DSC 600
¼tµP¡G¨ä¥L
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³­­¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z

°Ó «~ »¡ ©ú ¸ê ®Æ

NEXTA DSC¼ö¥Ü®t±½ºË¥d¶q­p(NEXTA DSC 600)


Differential Scanning Calorimeter (Heat Flux DSC)


Hitachi NEXTA DSC600

¡´ °ªÃ­©w«×ªº°ò½u¦A²{©Ê±5μW
¡´ µ´¨ÎªºÆF±Ó«×< 0.1 μW

HITACHI NEXTA DSC (Differential Scanning
Calorimeter)±Ä¨ú¼ö¬y¦¡³]­p¡A³z¹L¶q´ú¦UºØ§÷®Æ
¦b¤£¦P·Å«×¤Î®ðª^¤U©Ò²£¥Íªº§l©ñ¼ö¤ÏÀ³ÅܤơAÂÇ
¦¹±o¨ì§÷®Æ¬Á¼þÂಾ·Å«×¡Bº²ÂI¡Bº²¿Ä¼ö¡B¤ñ¼ö¡B
¥æÁp¤ÏÀ³µ¥¼ö¯S©Ê¡C
¥þ·sNEXTA DSC¥H¤T¼hª÷Äݹj¼öµ²ºc¡A·f°t½Æ¼Æ¹ï
ªº¼ö¹q°¸¡A¤j¤j´£°ªÀË´úªºÆF±Ó«×©Mí©w«×¡C
·f°t¦h¼Ë¤Æªº§N«o¨t²Î¡A´£¨Ñ¼e¼sªº·Å«×¶q´ú½d³ò
(-150~725¢J)¡C¦]À³«È¤á»Ý¨D¡A¤ä´©ÂX¥R¦Û°Ê¨ú¼Ë
¾¹¡B¼v¹³Æ[´ú¨t²Î¡BUV¥ú¨t²Î¡A¨¬¥H¦]À³¥Ø«e¥ô¦ó
³»¦yªº¾Ç³N¬ã¨s»P·~¬É¬ãµo«~ºÞ»Ý¨D¡C

yes ·Q¤F¸Ñ§ó¦h, Åwªï»P§Ú­Ì¬¢¸ß!!!                 

  DSC600 DSC200
Measurement principle Heat flux
Temperature range -150 -725¢J
DSC dynamic range +/-100mW +1-200mW
RMS noise/ Sensitivity 0.05μW / 0.1μw 0.1μW / 0.2μw
Calorimetric precision +/- 0.05%
* Calculated from the standard deviation (1a/average value in
In 10 consecutive measurement)

Baseline repeatability
(Electrical cooling unit)

+1/-5μW
* Electrical cooling unit : -50 ~ 300¢J, 10¢J/min
Programmable Rate 0.01 ~ 100¢J/min
Purge gas Air, Inert gas
Purge gas control Mass flow controller, 2 lines
Auto Sampler* Max.50 samples
Electrical Cooling Unit* -80 ~ 500¢J
Auto LN2 Gas Cooling Unit* -150 ~ 725¢J
Auto Air Cooling Unit* RT ~ 725¢J
* Optional  

 

¡@
°Ó «~ ¨ä ¥¦ ³Æ µù

¦PÃþ°Ó«~ >>
¡¹ ¡@ DMA°ÊºA¼ö¾÷±ñ¤ÀªR»ö(DMA 7100) ¡@
¡¹ ¡@ NEXTA DSC¼ö¥Ü®t±½ºË¥d¶q­p(NEXTA DSC 600) ¡@
¡¹ ¡@ DSC¼ö¥Ü®t±½ºË¥d¶q­p(DSC 7000X) ¡@
¡¹ ¡@ NEXTA STA¦P¨B¦¡¼ö­«-¼ö¥Ü®t¤ÀªR»ö(NEXTA STA200RV) ¡@
¡¹ ¡@ TMA¼ö¾÷±ñ¤ÀªR»ö(TMA 7000) ¡@

40449 ¥x¤¤¥«¥_°Ï¤å©÷ªF¤Gµó173¸¹ Tel:+886-4-2292-2214¡@¡@¡@Fax:+886-4-2292-1341¡@¡@¡@§K¶OªA°È¹q¸Ü¡G0800-286186
E-mail¡Gshotek.st@msa.hinet.net       2013-2020 © µ¾¶T»ö¾¹¦³­­¤½¥q Shotek Instrument Co., Ltd. All Rights Reserved    ¥»ºô¯¸¥Ñª¾»y¦³­­¤½¥q³]­p

¡@