Language¡G
¤½¥q²¤¶ ²£«~¤¶²Ð ³Ì·s®ø®§ ³Ì·s²£«~ «P¾P²£«~ ¼tµP¤¶²Ð ÀɮפU¸ü ³sµ¸§Ú­Ì ¦^­º­¶



¹q¸Ñ¦¡¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡½¤«p­p--¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
½¤«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h­«Âì«p«×¤Î¹q¦ì®t´ú©w²Õ¦X-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h¼hÂì¹qÁá­@»G»k´ú©w¸Ë¸m-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡¹qÁá«p«×´ú©w¾¹¥Î ¹q¸Ñ²G-¤¤¥¡»s§@©Ò
¶W­µªi²M¬~¾÷-¤¤¥¡»s§@©Ò
µL¹q¸ÑÂì¹qÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q·½¸Ë¸m/¾ã¬y¾¹-¤¤¥¡»s§@©Ò
¥ú¿A¾¯¦Û°Ê²K¥[¸Ë¸m-¤¤¥¡»s§@©Ò
PH/ORP±±»s¾¹-¤¤¥¡»s§@©Ò
¤T»ù»ÌÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q¸Ñ¤òÃä¥h°£¸Ë¸m-¤¤¥¡»s§@©Ò
ºÏ©Ê/«DºÏ©Ê/¨â¥Î«¬½¤«p­p
¶W­µªi¦h¼h½¤«p­p
X-ray¿Ã¥úÁá¼h´ú«p»ö
ÆQ¤ô¼QÃú¸ÕÅç¾÷
¥iµ{¦¡ùÚ·ÅùÚÀã¸ÕÅç¾÷
ºë±K¯M½c
Thickness Tester-Chuo Seisakusho.,LTD.
ùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù
¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u
¦Û°Êºw©w»ö-¤éªFºë¤u
Á`²¸¤ÀªR»ö-¤éªFºë¤u
Á`´â¤ÀªR»ö-¤éªFºë¤u
Á`´á¤ÀªR»ö-¤éªFºë¤u
¦Û°Ê¼Ë«~¿U¿N¸Ë¸m-¤éªFºë¤u
Á`¦³¾÷³¿¯À¤ÀªR»ö-¤éªFºë¤u
°ª/§Cªý§Ü²v­p-¤éªFºë¤u
¿n¤À²y¦¡¿B«×­p-¤éªFºë¤u
¤ô¥÷­p¥Î¹q¸Ñ²G¤Î¸Õ¾¯-¤éªFºë¤u
Á`¦³¾÷ºÒ¤ÀªR»ö-¤éªFºë¤u
³¿¯À¿O¤ô¥÷­p
¼ö¤ÀªR¨t¦C
¼ö¶Ç¾É«Y¼Æ¨t¦C
  ¤ÀÃþ >>  ¼ö¤ÀªR¨t¦C >> 
    ¦PÃþ°Ó«~ >> 
TMA 7000  TMA¼ö¾÷±ñ¤ÀªR»ö(TMA 7000) ¤H®ð«ü¼Æ 1283
«¬¸¹¡GTMA 7000
¤¤¤å¦WºÙ¡GTMA¼ö¾÷±ñ¤ÀªR»ö(TMA 7000)
­^¤å¦WºÙ¡GThermo Mechanical Analyzer TMA 7000
¼tµP¡G¨ä¥L
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³­­¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z

°Ó «~ »¡ ©ú ¸ê ®Æ

TMA/SS ¼ö¾÷±ñ¤ÀªR»ö(TMA 7000)


Thermo Mechanical Analyzer / Stress Strain

¼ö¾÷±ñ¤ÀªR»ö(Thermal Mechanical Analyzer)
¬°§÷®Æ¬ì¾Ç³Ì°ò¥»ªº´ú¶q¤u¨ã¤§¤@¡CTMA¯à´ú
¶q¥X¦UºØ¤£¦P§÷½è¼Ë«~«D±`·L¶qªº¤Ø¤oÅܤơB
À³¤OÀ³ÅÜ¡B¼çÅÜ´_­ì»P¾÷±ñÂH¼u©Êµ¥¦hºØ¼Æ¾Ú¡C
Á|¤Z¬O§÷®Æ¡A¨ä¿±µÈ¦¬ÁY¡B¤Ø¤o¦w©w©Êªº´ú¶q¡A
¶i¤@¨B¨ì½Æ¦X§÷®Æ¦p¹q¸ôªOªº­éÂ÷¡B¹q¤l´¹¤ù
«Ê¸Ë¡B§÷®Æ¦±Â¼µ¥²{¶H¡A¦UºØ§÷®Æ¤Ø¤o·|ÀH·Å
«×¦ÓÅܤƪº²£«~¡A¸g¥ÑTMAÀò±oªº§÷®Æ¯S©Ê¹ï
©ó¦UºØ²£«~³]­p¤Î»sµ{³£¯à´£¨Ñ·¥¬°­«­nªº´ú
¶q¸ê°T¡C

 
TMA7000

yes ·Q¤F¸Ñ§ó¦h, Åwªï»P§Ú­Ì¬¢¸ß!!!

Model name TMA7100 TMA7300
Temperature Range -170 to 600¢J Ambient to 1500¢J
Scanning Rate 0.01 to 100¢J/min
Sample Tube ㆍQuartz ㆍMetal*                                         ㆍAlumina ㆍQuartz*
Probe ㆍQuartz Expansion Probe
ㆍQuartz Penetration Probe*
ㆍQuartz Cone Probe*
ㆍQuartz Tension Probe*
ㆍQuartz Bending Probe* (to 500¢J)
ㆍVolume Expansion Accessory* (Ambient to 200¢J)
ㆍMetal Tension Probe*
ㆍAlumina Expansion Probe
ㆍQuartz Expansion Probe* (to 1000¢J)
ㆍQuartz Penetration Probe* (to 1000¢J)
ㆍQuartz Cone Probe* (to 1000¢J)
ㆍQuartz Tension Probe* (to 600¢J)
ㆍQuariz Bending Probe* (to 500¢J)
Probe Supporting Method Cantilever
TMA Measurement Range ±5mm
RMS noise / Sensitivity 0.005μm /0.01μm
Load Range / Resolution ±5.8N /9.8μN ±1,47N /9.8μN
Maximum Sample Dimensions Expansion, Penetration: D 10 x L 25mm
Tension: W5 x T1 x L 25mm
Expansion: D 10 x L 25mm
Sample Length Measurement Automated Measurement
Atmosphere ㆍAir, Inert gas flow
ㆍVacuum* (to 13Pa)
ㆍSwelling* (to 80¢J)
ㆍHumidity control* (to 90¢J, 90%RH)
ㆍAir, Inert gas flow
ㆍVacuum* (to 13Pa)
Stress Control Mode ㆍConstant Loading: ±5.8N ㆍConstant Rate Loading: 9.8 x 10-2 to 9.8 x 106mN/min
ㆍSinusoidal Loading: 0.001 to 1Hz ㆍCombination: maximum 40 steps
Strain Control Mode ㆍConstant Strain: ±5000μm ㆍConstant Rate Strain Control: 0.01 to 106μm/min
ㆍSinusoidal Strain Control: 0.001 to 1Hz ㆍCombination: maximum 40 steps
Gas Purge Control* ㆍFlow Meter ㆍGas Control Unit ㆍMass Flow Control Unit
Cooling Unit LN2 Dewar Vessel -170 to 600¢J N/A
Auto Fan Cooling Unit* Ambient to 600¢J Ambient to 1500¢J
Auto LN2 Gas Cooling Unit* -150 to 600¢J N/A
Electrical Cooling Unit* -60 to 450¢J N/A
*Optional    

 

¡@
°Ó «~ ¨ä ¥¦ ³Æ µù

¦PÃþ°Ó«~ >>
¡¹ ¡@ DMA°ÊºA¼ö¾÷±ñ¤ÀªR»ö(DMA 7100) ¡@
¡¹ ¡@ NEXTA DSC¼ö¥Ü®t±½ºË¥d¶q­p(NEXTA DSC 600) ¡@
¡¹ ¡@ DSC¼ö¥Ü®t±½ºË¥d¶q­p(DSC 7000X) ¡@
¡¹ ¡@ NEXTA STA¦P¨B¦¡¼ö­«-¼ö¥Ü®t¤ÀªR»ö(NEXTA STA200RV) ¡@
¡¹ ¡@ TMA¼ö¾÷±ñ¤ÀªR»ö(TMA 7000) ¡@

40449 ¥x¤¤¥«¥_°Ï¤å©÷ªF¤Gµó173¸¹ Tel:+886-4-2292-2214¡@¡@¡@Fax:+886-4-2292-1341¡@¡@¡@§K¶OªA°È¹q¸Ü¡G0800-286186
E-mail¡Gshotek.st@msa.hinet.net       2013-2020 © µ¾¶T»ö¾¹¦³­­¤½¥q Shotek Instrument Co., Ltd. All Rights Reserved    ¥»ºô¯¸¥Ñª¾»y¦³­­¤½¥q³]­p

¡@