¡@
 
Language¡G
¤½¥q²¤¶ ²£«~¤¶²Ð ³Ì·s®ø®§ ³Ì·s²£«~ «P¾P²£«~ ¼tµP¤¶²Ð ÀɮפU¸ü ³sµ¸§Ú­Ì ¦^­º­¶



¹q¸Ñ¦¡¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡½¤«p­p--¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
½¤«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h­«Âì«p«×¤Î¹q¦ì®t´ú©w²Õ¦X-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h¼hÂì¹qÁá­@»G»k´ú©w¸Ë¸m-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡¹qÁá«p«×´ú©w¾¹¥Î ¹q¸Ñ²G-¤¤¥¡»s§@©Ò
¶W­µªi²M¬~¾÷-¤¤¥¡»s§@©Ò
µL¹q¸ÑÂì¹qÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q·½¸Ë¸m/¾ã¬y¾¹-¤¤¥¡»s§@©Ò
¥ú¿A¾¯¦Û°Ê²K¥[¸Ë¸m-¤¤¥¡»s§@©Ò
PH/ORP±±»s¾¹-¤¤¥¡»s§@©Ò
¤T»ù»ÌÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q¸Ñ¤òÃä¥h°£¸Ë¸m-¤¤¥¡»s§@©Ò
ºÏ©Ê/«DºÏ©Ê/¨â¥Î«¬½¤«p­p
¶W­µªi¦h¼h½¤«p­p
X-ray¿Ã¥úÁá¼h´ú«p»ö
ÆQ¤ô¼QÃú¸ÕÅç¾÷
¥iµ{¦¡ùÚ·ÅùÚÀã¸ÕÅç¾÷
ºë±K¯M½c
Thickness Tester-Chuo Seisakusho.,LTD.
ùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù
¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u
¦Û°Êºw©w»ö-¤éªFºë¤u
Á`²¸¤ÀªR»ö-¤éªFºë¤u
Á`´â¤ÀªR»ö-¤éªFºë¤u
Á`´á¤ÀªR»ö-¤éªFºë¤u
¦Û°Ê¼Ë«~¿U¿N¸Ë¸m-¤éªFºë¤u
Á`¦³¾÷³¿¯À¤ÀªR»ö-¤éªFºë¤u
°ª/§Cªý§Ü²v­p-¤éªFºë¤u
¿n¤À²y¦¡¿B«×­p-¤éªFºë¤u
¤ô¥÷­p¥Î¹q¸Ñ²G¤Î¸Õ¾¯-¤éªFºë¤u
Á`¦³¾÷ºÒ¤ÀªR»ö-¤éªFºë¤u
³¿¯À¿O¤ô¥÷­p
¼ö¤ÀªR¨t¦C
¼ö¶Ç¾É«Y¼Æ¨t¦C
  ¤ÀÃþ >>  ¼ö¤ÀªR¨t¦C >> 
    ¦PÃþ°Ó«~ >> 
DSC 7000X  DSC¼ö¥Ü®t±½ºË¥d¶q­p(DSC 7000X) ¤H®ð«ü¼Æ 1489
«¬¸¹¡GDSC 7000X
¤¤¤å¦WºÙ¡GDSC¼ö¥Ü®t±½ºË¥d¶q­p(DSC 7000X)
­^¤å¦WºÙ¡GDifferential Scanning Calorimeter DSC 7000X
¼tµP¡G¨ä¥L
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³­­¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z

°Ó «~ »¡ ©ú ¸ê ®Æ

DSC ¼ö¥Ü®t±½ºË¥d¶q­p(DSC 7000X)


Differential Scanning Calorimeter

          
DSC 7000X            

°ª·P«×¼ö¬y¦¡DSC 7000 Series (Heat Flux DSC)

DSC(Differential Scanning Calorimeter)±Ä¨ú¼ö¬y
¦¡³]­p¡A³z¹L¶q´ú¦UºØ§÷®Æ¦b¤£¦P·Å«×¤Î®ðª^¤U©Ò
²£¥Íªº§l©ñ¼ö¤ÏÀ³ÅܤơAÂǦ¹±o¨ì§÷®Æ¬Á¼þÂಾ·Å
«×¡Bº²ÂI¡Bº²¿Ä¼ö¡B¤ñ¼ö¡B¥æÁp¤ÏÀ³µ¥¼ö¯S©Ê¡C
HITACHI DSC7000X¥H¤T¼hª÷Äݹj¼öµ²ºc¡A·f°t½Æ
¼Æ¹ïªº¼ö¹q°¸¡A¤j¤j´£°ªÀË´úªºÆF±Ó«×©Mí©w«×¡C
·f°t¦h¼Ë¤Æªº§N«o¨t²Î¡A´£¨Ñ¼e¼sªº·Å«×¶q´ú½d³ò
(-150~725¢J)¡C¦]À³«È¤á»Ý¨D¡A¤ä´©ÂX¥R¦Û°Ê¨ú¼Ë
¾¹¡B¼v¹³Æ[´ú¨t²Î¡BUV¥ú¨t²Î¡A¨¬¥H¦]À³¥Ø«e¥ô¦ó
³»¦yªº¾Ç³N¬ã¨s»P·~¬É¬ãµo«~ºÞ»Ý¨D¡C


  yes ·Q¤F¸Ñ§ó¦h, Åwªï»P§Ú­Ì¬¢¸ß!!!                                                                                                              

Model name DSC7020 DSC7000X
Heat Flow Measurement Method Heat flux
Temperature Range -170 to 725¢J -150 to 725¢J
Temperature Precision (Indium) ±0.2¢J ±0.1¢J
DSC Measurement Range ±350mW ±100mW
RMS noise / Sensitivity 0.1μW/0.2μW 0.05μW/0.1μW
Calorimetric Repeatability (Indium) 0.3J/g 0.1J/g
Scanning Rate 0.01 to 100¢J/min
Atmosphere Air, Inert gas flow
Sample Pans* ㆍOpen pans (Aluminum, Platinum, Alumina)
ㆍ Low-Pressure sealed pans (Aluminum, Chromated Aluminum)
ㆍ High-Pressure sealed pans (Aluminum, Silver, Stainless-steel, Gold-plated stainless-steel)
Gas Purge Control* ㆍFlow Meter ㆍGas Control Unit ㆍMass Flow Control Unit
Cooling Unit* Cooling can -170 to 725¢J N/A
Forced Air Cooling Unit Ambient to 725¢J
Auto LN2 Gas Cooling Unit -150 to 725¢J
Electrical Cooling Unit -70 t0 420¢J -80 to 500¢J
Auto Sampler Unit* Available (max. 50samples, Mechanical arm transport, Quench cooling)
Real View Sample Observation Unit* Available
PDC-7 UV Irradiation Unit* Available
*Optional    

 

 

¡@
°Ó «~ ¨ä ¥¦ ³Æ µù

¦PÃþ°Ó«~ >>
¡¹ ¡@ DMA°ÊºA¼ö¾÷±ñ¤ÀªR»ö(DMA 7100) ¡@
¡¹ ¡@ NEXTA DSC¼ö¥Ü®t±½ºË¥d¶q­p(NEXTA DSC 600) ¡@
¡¹ ¡@ DSC¼ö¥Ü®t±½ºË¥d¶q­p(DSC 7000X) ¡@
¡¹ ¡@ NEXTA STA¦P¨B¦¡¼ö­«-¼ö¥Ü®t¤ÀªR»ö(NEXTA STA200RV) ¡@
¡¹ ¡@ TMA¼ö¾÷±ñ¤ÀªR»ö(TMA 7000) ¡@

40449 ¥x¤¤¥«¥_°Ï¤å©÷ªF¤Gµó173¸¹ Tel:+886-4-2292-2214¡@¡@¡@Fax:+886-4-2292-1341¡@¡@¡@§K¶OªA°È¹q¸Ü¡G0800-286186
E-mail¡Gshotek.st@msa.hinet.net       2013-2020 © µ¾¶T»ö¾¹¦³­­¤½¥q Shotek Instrument Co., Ltd. All Rights Reserved    ¥»ºô¯¸¥Ñª¾»y¦³­­¤½¥q³]­p

¡@