Language¡G
¤½¥q²¤¶ ²£«~¤¶²Ð ³Ì·s®ø®§ ³Ì·s²£«~ «P¾P²£«~ ¼tµP¤¶²Ð ÀɮפU¸ü ³sµ¸§Ú­Ì ¦^­º­¶



¹q¸Ñ¦¡¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡½¤«p­p--¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
½¤«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h­«Âì«p«×¤Î¹q¦ì®t´ú©w²Õ¦X-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h¼hÂì¹qÁá­@»G»k´ú©w¸Ë¸m-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡¹qÁá«p«×´ú©w¾¹¥Î ¹q¸Ñ²G-¤¤¥¡»s§@©Ò
¶W­µªi²M¬~¾÷-¤¤¥¡»s§@©Ò
µL¹q¸ÑÂì¹qÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q·½¸Ë¸m/¾ã¬y¾¹-¤¤¥¡»s§@©Ò
¥ú¿A¾¯¦Û°Ê²K¥[¸Ë¸m-¤¤¥¡»s§@©Ò
PH/ORP±±»s¾¹-¤¤¥¡»s§@©Ò
¤T»ù»ÌÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q¸Ñ¤òÃä¥h°£¸Ë¸m-¤¤¥¡»s§@©Ò
ºÏ©Ê/«DºÏ©Ê/¨â¥Î«¬½¤«p­p
¶W­µªi¦h¼h½¤«p­p
X-ray¿Ã¥úÁá¼h´ú«p»ö
ÆQ¤ô¼QÃú¸ÕÅç¾÷
¥iµ{¦¡ùÚ·ÅùÚÀã¸ÕÅç¾÷
ºë±K¯M½c
Thickness Tester-Chuo Seisakusho.,LTD.
ùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù
¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u
¦Û°Êºw©w»ö-¤éªFºë¤u
Á`²¸¤ÀªR»ö-¤éªFºë¤u
Á`´â¤ÀªR»ö-¤éªFºë¤u
Á`´á¤ÀªR»ö-¤éªFºë¤u
¦Û°Ê¼Ë«~¿U¿N¸Ë¸m-¤éªFºë¤u
Á`¦³¾÷³¿¯À¤ÀªR»ö-¤éªFºë¤u
°ª/§Cªý§Ü²v­p-¤éªFºë¤u
¿n¤À²y¦¡¿B«×­p-¤éªFºë¤u
¤ô¥÷­p¥Î¹q¸Ñ²G¤Î¸Õ¾¯-¤éªFºë¤u
Á`¦³¾÷ºÒ¤ÀªR»ö-¤éªFºë¤u
³¿¯À¿O¤ô¥÷­p
¼ö¤ÀªR¨t¦C
¼ö¶Ç¾É«Y¼Æ¨t¦C
  ¤ÀÃþ >>  Á`²¸¤ÀªR»ö-¤éªFºë¤u >> Á`´â/²¸¤ÀªR»ö TCL-2100V«¬ >> 
    ¦PÃþ°Ó«~ >> 
TCL-2100V  Á`´â/²¸¤ÀªR»ö TCL-2100V«¬ ¤H®ð«ü¼Æ 5335
«¬¸¹¡GTCL-2100V
¤¤¤å¦WºÙ¡GÁ`´â/²¸¤ÀªR»ö TCL-2100V«¬
­^¤å¦WºÙ¡GTrace Chlorine/Sulfur Analyzer
¼tµP¡G¤éªFºë¤u¤ÀªR¬ì§Þ
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³­­¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z

°Ó «~ »¡ ©ú ¸ê ®Æ

 



¨ã¦³¤@©wµû»ù¤§ÂÇ®w­Ûªk¤è¦¡Â²³æ´ú©w²GÅé¡A®ðÅ餤¤§·L¶q®ð¤Î²¸§t¶q¡C

¥Ûªo¤Æ¾Ç¤u¼t¡A¤Æ¾Ç»s³y¼t§÷®Æ»s³y¼tµ¥…¡A¨Ï©Ò¦³¤§²£·~ïH°ì¬¡ÅD¡C

²Å¦X¦p¤U¤§¤½©wªk¡G

CI¡GASTM D5808, JPI 5S-64-02, TS K0010

S ¡GASTM D3120, 3140, JIS K2541, 2240

¯S ÂI¡G

  • Àu½èµøµ¡¾Þ§@©Ê¡A¥\¯à´£ª@

  • ¨t²Î¨ÌÀ³¥Î¥Øªººc¦¨

  • ¦Û°Ê¦à±±»s¡A§Ö³t¤ÀªR

  • ¤À³ÎÄl³]­p¡A«O¾i´£¤É

¥K¼Ë

°Ó«~¦WºÙ¡G

Á`´â/²¸¤ÀªR»ö TCL-2100V«¬
Trace Chlorine/Sulfur Analyzer
¡m««ª½Äl¿U¿N¤è¦¡¡n

¼Ò«¬¡G

´â¤ÀªR¸Ë¸m

²¸¤ÀªR¸Ë¸m

´ú©w¹ï¶H¸Õ®Æ¡G

²GÅé¤Î®ðÅé¼Ë«~

¤ÀªR¤èªk¡G

®ñ¤Æ¤À¸Ñ¡B¹q¶qºw©w

ÀË¥Xªk¡G

®ñ¤ÆÁÙ¤¸¹q¦ì(¥Ñ¹q·¥¤§¹q¦ì®tÀË¥X)

¿U¿NÄl·Å«×¡G

¶}³¬¦¡¹q®ðÄl¡G¤G¤À³Î¤è¦¡¡B·Å«×³Ì°ª¡G1,100¡C C(¼Ë«~ª`¤J³¡¤Î¤ÏÀ³³¡¥i­Ó§O³]©w)

ÀË¥X¹q·¥¡G

´â¯À´ú©w¡G»È¹q·¥

´ú©w½d³ò¡G

0.01~50μm

³q±`¤§¸Õ®Æ¡G1,000¡C C ¥H¤U¿U¿N¬O¤£§t§«®`¿U¿N¤§¼Ë«~)

0.02~20μm

³q±`¤§¸Õ®Æ¡G1,000¡C C ¥H¤U¿U¿N¬O¤£§t§«®`¿U¿N¤§¼Ë«~)

¸Õ®Æ¶q¡G

¨Ì¿ïÁʸ˸m¦Ó²§¡A¨Ì¿ïÁʸ˸m½T©wª`¤J¶q

´ú©w®É¶¡¡G

10¤À¥H¤º/¥ó(2μg´ú©w®É)*2

¨Ï¥Î®ðÅé¡G

´ã®ð(¯Â«×99.8%¥H¤W¡A200~400kPa)

®ñ®ð(¯Â«×99.7%¥H¤W¡A200~400kPa)

¹q·½¡G

VF-210 AC100/115/230/240V¡B50/60Hz¡B1,000VA

MCD-210 AC100/115/230//240V¡B50/60Hz¡B150VA

¤oªk·½è¶q¡G

VF-210 ¬ù500(W)¢®430(D)¢®500(H)mm¡B¬ù35kg

MCD-210 ¬ù220(W)¢®375(D)¢®500(H)mm¡B¬ù14kg

 

 

¿ïÁÊ«~
GI-210 ®ðÅéª`¤J¾¹

 

ASC-250L ²GÅé¥Î¦Û°Ê¼Ë«~Âà´«¾¹

 

GI-220 ®ðÅéª`¤J¾¹

 

¡@
¡@
 TCL-2100V

               New instrument TCL-2100V can measure total chlorine/sulfur from trace level in fast, easy way. It can be applicable to variety of liquid and gaseous samples by approved coulometric analysis.

                                                        CI¡GASTM D5808, JPI 5S-64-02, TS K0010

                                                        S ¡GASTM D3120, 3140, JIS K2541, 2240

Features¡G

•         Trace chlorine measurement down to 0.05 ppm in Liquid sample.

•         Application-oriented system configuration.

•         Accurate and stable analysis

•         Fully automated running

•         Data output for LIMS*

•         Energy saving, cut useless electric power consumption and gases.

 Standard specification

Model¡G

TCL-2100V
Trace Chlorine/Sulfur Analyzer

Analysis method¡G

Oxidative decomposition

coulometric titration

Applicable sample*¡G

liquid, non pressurized gas

Detection method¡G

Potential difference by electrodes (oxidation-reduction potential)

Pyrolysis furnace¡G

Open-close electric furnace: two parts, max 1100 °C. (Individually controlled for injection and pyrolysis)

Detection electrodes ¡G

Chlorine: Silver

Sulfur: Platinum

Measuring range¡G

Chlorine: 0.01 50 μg (0.05 1000ppm)

Sulfur: 0.02 50 μg (0.11000ppm)

Measuring time¡G

< 10 min at 2 μg*

Gas¡G

Argon: 200 400 kPa, > 99.98% purity / Oxigen: 200 400 kPa, >99.7% purity

Power¡G

VF-210; AC 100/115/230/240V, 50/60 Hz, 1000VA

MCD-210; AC 100/115/230/240V, 50/60 Hz, 150VA

Dimension and

Weight¡G

VF-210; Approx. 500(W) x 430(D) x 500(H)mm, Approx. 35kg

MCD-210; Approx. 220(W) x 375(D) x 500(H)mm, Approx. 14kg

 

 

Option

GI-210 (Gas Injector)

 

   Gaseous sample will be injected by gastight syringe manually into inert gas to ensure safety.

ASC-250L (Liquid Auto Sample Changer)

 

Liquid sample can be measured fully automatically from sampling to injection and rinsing. Microsyringe handles up to 200 μl injection and 50 vials can be placed for complete automation of sampling.

GI-220 (Gas Injector)

   Gaseous sample will be injected by syringe pump for

automatic measuring. Injection line can be purged by

next sample for measurement.

 

¡@
°Ó «~ ¨ä ¥¦ ³Æ µù

¦PÃþ°Ó«~ >>
¡¹ ¡@ Á`´â/²¸¤ÀªR»ö TCL-2100V«¬ ¡@

40449 ¥x¤¤¥«¥_°Ï¤å©÷ªF¤Gµó173¸¹ Tel:+886-4-2292-2214¡@¡@¡@Fax:+886-4-2292-1341¡@¡@¡@§K¶OªA°È¹q¸Ü¡G0800-286186