KF-200 ¥d¦¡·L¶q¤ô¥÷p KF-200«¬ (®e¿nªk) |
¤H®ð«ü¼Æ |
5941 |
|
|
«¬¸¹¡GKF-200 |
¤¤¤å¦WºÙ¡G¥d¦¡·L¶q¤ô¥÷p KF-200«¬ (®e¿nªk) |
^¤å¦WºÙ¡GKarl-Fischer Volumetric titration |
¼tµP¡G¤éªFºë¤u¤ÀªR¬ì§Þ |
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z |
|
|
|
|
°Ó «~ »¡ ©ú ¸ê ®Æ |
|
|
°Ó«~³W®æ |
°Ó«~¦WºÙ¡G
|
¥d¦¡·L¶q¤ô¥÷p KF-200«¬ (®e¿nªk)
Karl-Fischer Volumetric titration
¡m¥iÂùÀW¹D¦P®É´ú©w¡B¦P®Éªí¥Ü¡n
|
¯SÂI¡G
|
KF-200(³æÀW¹D)¥iÃB¥~¼W¥[¤@²Õºw©wªk¡A¦w¸Ë¦¨ÂùÀW¹D¡A
§Y¥i¦P®É´ú©w"®e¿nªk-®e¿nªk"…µ¥¡C
³]¦³USB´¡¼Ñ¡A¤è«K±NÀË´úµ²ªG¥HCSV®æ¦¡Àx¦s(ÀÉ®×¥i©óExcel¶}±ÒºÞ²z)¡C
|
¿Ã¹õ¡G
|
5.7¦T±m¦âLCD¿Ã¹õ¥i¥H²M·¡Åã¥Ü´ú©w¸ê®Æ |
«¶q¡G
|
¬ù 9.5kg |
¤Ø¤o¡G
|
¬ù 578 W× 320 D× 350 Hmm |
|
|
|
¡@ |
|
KF-200¡mDual Channel Measurement & Dual Channel Display¡n |
The dual channel Karl Fischer Moisture System has further development to complete the system. One unit of system perfectly cover the function of two systems by using Color LCD display. And more over the foot print is much smaller than two units.
Dual Channel Simultaneous Measurement (Patent Pending)
Simply adding a titration unit to the CA-200/KF-200 single channel system makes it possible to configure a dual channel system. The 5.7-inch color LCD clearly show the status of both channels.
*:Allows back-titration
Features
We completed Dual Channel system for simultaneous measurement.
5.7-Inch Color Liquid Crystal Monitor
Help Function
Electrode Conditioning Function (Patent Pending)
VA-230 Vial-Compatible Water Vaporizer
GLP Support Functions
USB Memory for Storage Media
Standard Equipment Printer
Stepped Temperature Control
Use of a Syringe Burette for Improved Accuracy
Liquid Dispenser and Disposal Unit (Option)
|
|
KF-200 Specifications ¡mVolumetric Moisture Meter¡n |
|
Measurement method:
|
Volumetric Karl-Fischer titration,
2-channel simultaneous measurement (option) |
|
Control method: |
Detection Voltage proportional control |
|
Detection method: |
Constant current polarization potential difference |
|
Measuring range: |
0.1-999mgH2O |
|
Stirring method: |
Magnetic stirrer |
|
Titration flask: |
Volume: 150ml |
|
Display: |
5.7-inch color liquid crystal monitor |
|
File configuration: |
20 files, 50 multi-files |
|
Calculation functions: |
Calculation of concentration, statistical calculation, recalculation |
|
Printer: |
Built-in thermal printer |
|
Vaporizer operating
functions: |
Temperature range of VA-200, VA-210 or VA-124S, measurements can be grouped for VA-124S
(stepped temperature control available for each vaporizer) |
|
Burette: |
Syringe type
Volume: 10ml (option: 25ml)
Discharge rate: ml/1.5sec, aspiration rate: ml/1.5sec
Accuracy: ±0.02ml (10ml syringe) |
|
External I/O: |
Electronic balance: Automatic weight input
Dedicated USB memory port: Storage of measurement results, import/export of settings
Computer: RS-232C interface (option) |
|
Additional functions: |
GLP support function, help function, detection electrode conditioning |
|
Operating environment: |
Temperature: 5-40oC
Relative humidity: Up to 85% with no condensation of moisture |
|
Dimensions, Weight: |
Main Unit: Approx. 330(W)× 320(D)× 148(H) mm, 5kg
Stirrer: Approx. 120(W)× 180(D)× 148(H) mm, 1kg
KF burette: Approx. 108(W)× 320(D)× 275(H) mm, 3.5kg |
|
|
Options |
|
Sample Boat Type
model VA-200
Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples
Heating temperature: 70~300oC
Heater: Transparent electro-conductive glass 150W
Sample size: Up to 10g
Measuring range: From 5ppm (when used in combination with CA-200)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Gas dryer: Desiccant (Sicapent®) tube, 1
Dimensions, Weight: approx. 303(W)× 112(D)× 131(H) mm, 5.5kg
|
|
Disposable Vial Type
model VA-230
Enables easy measurement using disposable vials. Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples
Heating temperature: 70~300oC
Heater: Aluminum block heater 60W×2
Sample size: Up to 10g and 2.5ml volume, vial volume:10ml
Measuring range: From 30ppm (when used in combination with CA-200)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Gas dryer: Desiccant (Sicapent®) tube, 1
Dimensions, Weight: approx. 300(W)× 130(D)× 240(H) mm, 4kg
|
|
Autosamplers and Vaporizers
model VA-236S
Automatic and consecutive measurements up to 33 samples(Vials).Carrier gas is controlled by a mass flow controller, realizing a stable flow rate regardless of the gas pressure.
Platics, rubbers, food products, medical products, inorganic salts, powders, and other solid samples can be measured. Certain oil samples can also be measured using a special needle.
Heating temperature: 70~300oC
Gas flow: 0 to 500ml/min(set from moisture meter)
Carrier gas: Nitrogen gas, <0.01 % moisture
Carrier control: Mass flow controller
Vials(10ml): Total 36, including purge vials
Sample size: <10g and < 2.5ml in volume(solids) < 5ml(oils)
Power supply: AC 100-120V, 200VA/AC220-240V, 250VA
Dimensions: 370(W)*560(D)*400(H) mm
Weight: 18kg
|
|
Autosamplers and Vaporizers
model VG-200
Ideal injector for propane, butane, and other liquefied gases. A predefined amount of LPG will be vaporized and injected into the moisture meter.
Applicable gases: Propane. Butane,other liquefide gases(Up to 5 different gas factors can be set)
Injection rate: 100 to 600ml/min
Injection volume: 1 to 99L
Heater temperature: 40 to 90¢J
Power supply: AC100-120V, 40VA/ AC220-240V, 20VA
Dimensions: 150(W)*350(D)*270(H) mm
Weight: 6 kg
|
|
High Temperatures
model VA-121
Iron ore, clay, metal oxides, inorganic salts
Heating temperature: 250~300oC
Heater: Electric Furnace (Kanthal wire) 800W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 420(W)× 260(D)× 240(H) mm, 15.5kg
|
|
High/Low Temperatures
model VA-122
Enables measurement of ancillary moisture. Iron ore, clay, welding rods, metal oxides, inorganic salts
Heating temperature: 70~300oC, 250~1000oC
Heater: Electric Furnace (Kanthal wire) 1000W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 5ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 690(W)× 290(D)× 410(H) mm, 20kg
|
|
Additional Power Supply Unit
model CAEPWA
Dimensions: approx. 310(W)× 170(D)× 150(H) mm
Weight: approx. 3kg
|
|
Liquid Dispenser and Disposal Unit CAESD
model CAESD
Dimensions, Weight: approx. 90(W)× 120(D)× 80(H) mm, 708kg
¡°can be used for Cuolometric(fritless), and Volumetric
|
|
|
|
¡@ |
°Ó «~ ¨ä ¥¦ ³Æ µù |
|
|
|