Language¡G
¤½¥q²¤¶ ²£«~¤¶²Ð ³Ì·s®ø®§ ³Ì·s²£«~ «P¾P²£«~ ¼tµP¤¶²Ð ÀɮפU¸ü ³sµ¸§Ú­Ì ¦^­º­¶



¹q¸Ñ¦¡¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡½¤«p­p--¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
½¤«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h­«Âì«p«×¤Î¹q¦ì®t´ú©w²Õ¦X-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h¼hÂì¹qÁá­@»G»k´ú©w¸Ë¸m-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡¹qÁá«p«×´ú©w¾¹¥Î ¹q¸Ñ²G-¤¤¥¡»s§@©Ò
¶W­µªi²M¬~¾÷-¤¤¥¡»s§@©Ò
µL¹q¸ÑÂì¹qÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q·½¸Ë¸m/¾ã¬y¾¹-¤¤¥¡»s§@©Ò
¥ú¿A¾¯¦Û°Ê²K¥[¸Ë¸m-¤¤¥¡»s§@©Ò
PH/ORP±±»s¾¹-¤¤¥¡»s§@©Ò
¤T»ù»ÌÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q¸Ñ¤òÃä¥h°£¸Ë¸m-¤¤¥¡»s§@©Ò
ºÏ©Ê/«DºÏ©Ê/¨â¥Î«¬½¤«p­p
¶W­µªi¦h¼h½¤«p­p
X-ray¿Ã¥úÁá¼h´ú«p»ö
ÆQ¤ô¼QÃú¸ÕÅç¾÷
¥iµ{¦¡ùÚ·ÅùÚÀã¸ÕÅç¾÷
ºë±K¯M½c
Thickness Tester-Chuo Seisakusho.,LTD.
ùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù
¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u
¦Û°Êºw©w»ö-¤éªFºë¤u
Á`²¸¤ÀªR»ö-¤éªFºë¤u
Á`´â¤ÀªR»ö-¤éªFºë¤u
Á`´á¤ÀªR»ö-¤éªFºë¤u
¦Û°Ê¼Ë«~¿U¿N¸Ë¸m-¤éªFºë¤u
Á`¦³¾÷³¿¯À¤ÀªR»ö-¤éªFºë¤u
°ª/§Cªý§Ü²v­p-¤éªFºë¤u
¿n¤À²y¦¡¿B«×­p-¤éªFºë¤u
¤ô¥÷­p¥Î¹q¸Ñ²G¤Î¸Õ¾¯-¤éªFºë¤u
Á`¦³¾÷ºÒ¤ÀªR»ö-¤éªFºë¤u
³¿¯À¿O¤ô¥÷­p
¼ö¤ÀªR¨t¦C
¼ö¶Ç¾É«Y¼Æ¨t¦C
  ¤ÀÃþ >>  ¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u >> ¥d¦¡·L¶q¤ô¥÷­p CA-200«¬ (®w­Ûªk) >> 
    ¦PÃþ°Ó«~ >> 
CA-200  ¥d¦¡·L¶q¤ô¥÷­p CA-200«¬ (®w­Ûªk) ¤H®ð«ü¼Æ 6911
«¬¸¹¡GCA-200
¤¤¤å¦WºÙ¡G¥d¦¡·L¶q¤ô¥÷­p CA-200«¬ (®w­Ûªk)
­^¤å¦WºÙ¡GKarl-Fischer Coulometric titration
¼tµP¡G¤éªFºë¤u¤ÀªR¬ì§Þ
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³­­¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z

°Ó «~ »¡ ©ú ¸ê ®Æ
¥d¦¡¤ô¥÷­p CA-200
°Ó«~³W®æ

°Ó«~¦WºÙ¡G

¥d¦¡·L¶q¤ô¥÷­p CA-200«¬ (®w­Ûªk)
Karl-Fischer Coulometric titration
¡m¥iÂùÀW¹D¦P®É´ú©w¡B¦P®Éªí¥Ü¡n

¯SÂI¡G

CA-200(³æÀW¹D)¥iÃB¥~¼W¥[¤@²Õºw©wªk¡A¦w¸Ë¦¨ÂùÀW¹D¡A§Y¥i¦P®É´ú©w"®w­Ûªk-®w­Ûªk"¡B"®w­Ûªk-®e¿nªk"…µ¥¡C
³]¦³USB´¡¼Ñ¡A¤è«K±NÀË´úµ²ªG¥HCSV®æ¦¡Àx¦s(ÀÉ®×¥i©óExcel¶}±ÒºÞ²z)¡C

¿Ã¹õ¡G
5.7¦T±m¦âLCD¿Ã¹õ¥i¥H²M·¡Åã¥Ü´ú©w¸ê®Æ
­«¶q¡G
¬ù 6kg
¤Ø¤o¡G
¬ù 460 W× 320 D× 300 Hmm
 
 
½Ð¿ï¥Î¤TµÙ¤ô¥÷»ö±M¥Î¤§ ¶§³±·¥²G¡Bºw©w²G¡B²æ¤ô·»¾¯¤Î¼Ð·Ç«~…µ¥¸Õ¾¯

¿ïÁÊ«~


VA-200
VA-200 ¼Ë«~¦à¥[¼ö»]µo¸Ë¸m
¤Ø¤o¡G¬ù 303W× 112 D× 131 Hmm
­«¶q¡G¬ù 5.5 kg
¥[¼ö·Å«×¡G70°C¡ã300°C
¸Õ®Æ¶q¡G10g ¥H¤U
´ú©w½d³ò¡G5ppm ¥H¤W
¾A¥Î¼Ë«~¡G¦UºØ­¹«~¡BµL¾÷ÆQÃþ¡BÂåÃÄ«~…µ¥¯»¥½/©TÅé¼Ë¥»

VA-230
VA-230¼Ë«~²~¥[¼ö»]µo¸Ë¸m
¤Ø¤o¡G¬ù 300W× 135 D× 220 Hmm
­«¶q¡G¬ù 3.5 kg
¥[¼ö·Å«×¡G70°C¡ã300°C
¸Õ®Æ¶q¡G10g ©Î 2.5ml ¥H¤U
´ú©w½d³ò¡G30ppm ¥H¤W
¾A¥Î¼Ë«~¡G¦UºØ­¹«~¡BµL¾÷ÆQÃþ¡BÂåÃÄ«~…µ¥¯»¥½/©TÅé¼Ë¥»

VA-24VS
VA-236S¦Û°Ê¼Ë«~²~¥[¼ö»]µo¸Ë¸m(¦hÀËÅé)
¤Ø¤o¡G¬ù 370W× 560 D× 400 Hmm
­«¶q¡G¬ù 18 kg
¥[¼ö·Å«×¡G70¡ã300°C
¸Õ®Æ¶q¡G¡G<10g and <2.5ml in volume (solids) <5ml (oils)
Vials (10ml)¡GTotal 33, including purge vials
¾A¥Î¼Ë«~¡G¥i³sÄòÀË´ú33ºØ¼Ë«~¡A¡]¤@¯ë©TÅé¥Î¡^¦UºØ­¹«~¡BµL¾÷ÆQÃþ¡BÂåÃÄ«~…µ¥¯»¥½/©TÅé¼Ë¥»¡C

VA-121
VA-121°ª·Å¦¡¥[¼ö»]¼ö¸Ë¸m
¤Ø¤o¡G¬ù 420W× 260 D× 240 Hmm
­«¶q¡G¬ù 15.5 kg
¥[¼ö·Å«×¡G250°C¡ã1000°C
¸Õ®Æ¶q¡G10g ¥H¤U
´ú©w½d³ò¡G10ppm ¥H¤W
¾A¥Î¼Ë«~¡G(°ª·Å¥Î)ÅKÄq¡BÂH¤g¡Bª÷ÄÝ®ñ¤Æª«¤ÎµL¾÷ÆQÃþ…

VA-122
VA-122°ª/§C·ÅÂùÄl¦¡¥[¼ö»]¼ö¸Ë¸m
¤Ø¤o¡G¬ù690W× 290 D× 410 Hmm
­«¶q¡G¬ù20 kg
¥[¼ö·Å«×¡G70°C¡ã300°C, 250~1000°C
¸Õ®Æ¶q¡G10g ¥H¤U
´ú©w½d³ò¡G5ppm ¥H¤W
¾A¥Î¼Ë«~¡GÅKÄq¡BÂH¤g¡B²k±ì¡Bª÷ÄÝ®ñ¤Æª«¤ÎµL¾÷ÆQÃþ…

CA-200/KF-200ªþ¥[¹q·½¨Ñµ¹
CA-200/KF-200 ªþ¥[¹q·½¨Ñµ¹
¤Ø¤o¡G¬ù 310W× 170 D× 150 Hmm
­«¶q¡G¬ù 3 kg

VA-122
VG-200²G¤Æ®ðÅé®ð¤Æ¸Ë¸m
¤Ø¤o¡G¬ù150W× 350 D× 270 Hmm
­«¶q¡G¬ù 6 kg
¥[¼ö·Å«×¡G40°C¡ã90°C
Injection rate:100 to 600ml/min
Injection volume:1 to 99L
Ideal infector for propane, butane, and other liquefied gases. A predefined amount of LPG will be vaporized and injected into the moisture meter.

VA-210
KF-200¥Î¸Õ¾¯¶ñ¥Rº[¼o²G©â¨ú¸Ë¸m
 
 
 
 
 
 

 

 

 

¡@

 

  CA-200¡mDual Channel Measurement & Dual Channel Display¡n

The dual channel Karl Fischer Moisture System has further development to complete the system. One unit of system perfectly cover the function of two systems by using Color LCD display. And more over the foot print is much smaller than two units.

Dual Channel Simultaneous Measurement (Patent Pending)
Simply adding a titration unit to the CA-200/KF-200 single channel system makes it possible to configure a dual channel system. The 5.7-inch color LCD clearly show the status of both channels.

CA-200

*:Allows back-titration

 

Features
We completed Dual Channel system for simultaneous measurement.
5.7-Inch Color Liquid Crystal Monitor
Help Function
Electrode Conditioning Function (Patent Pending)
VA-230 Vial-Compatible Water Vaporizer
GLP Support Functions
USB Memory for Storage Media
Standard Equipment Printer
Stepped Temperature Control
Moisture Measurement Using Single-Liquid reagent (Optional Electrode)

 

 
 CA-200 Specifications ¡mCoulometric Moisture Meter¡n

Measurement method: 
Coulometric Karl-Fischer titration,
2-channel simultaneous measurement (option)

Control method:  Constant Current pulse time control

Detection method:  Constant current polarization potential difference

Electrolysis current:  430mA 

Titration rate:  Avg. 2.2mgH2O /min (36μgH2O/sec.)

Background:  Automatic correction, constant display,
background display at start of measurement

Measuring range:  10μg to 100mgH2O

Detection sensitivity:  0.1μgH2O

Accuracy:  Up to 0.3% CV at 1mg or more (n=10)

Stirring method:  Magnetic stirrer

Titration cell:  Volume: 150ml  

Display:  5.7-inch color liquid crystal monitor  

File configuration:  20 files, 50 multi-files

Calculation functions:  Calculation of concentration, statistical calculation, recalculation

Printer:  Built-in thermal printer

Vaporizer operating  
functions: 
Temperature range of VA-200, VA-210 or VA-236S,
(stepped temperature control available for each vaporizer)

External I/O:  Electronic balance: Automatic weight input
Dedicated USB memory port: Storage of measurement results, import/export of settings

Additional functions:  Computer: RS232 interface (option)
GLP support function, help function, detection electrode conditioning

Operating environment:  Temperature: 5-40oC
Relative humidity: Up to 85% with no condensation of moisture

Dimensions, Weight:  Main Unit: Approx. 330(W)× 320(D)× 148(H) mm, 5kg
Stirrer: Approx. 120(W)× 180(D)× 148(H) mm, 1kg

 
Options

Sample Boat Type VA-200
model VA-200

Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples

Heating temperature: 70~300oC
Heater: Transparent electro-conductive glass 150W
Sample size: Up to 10g
Measuring range: From 5ppm (when used in combination with CA-200)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Gas dryer: Desiccant (Sicapent®) tube, 1
Dimensions, Weight: approx. 303(W)× 112(D)× 131(H) mm, 5.5kg


Disposable Vial Type VA-230
model VA-230

Enables easy measurement using disposable vials. Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples

Heating temperature: 70~300oC
Heater: Aluminum block heater 60W×2
Sample size: Up to 10g and 2.5ml volume, vial volume:10ml
Measuring range: From 30ppm (when used in combination with CA-200)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Gas dryer: Desiccant (Sicapent®) tube, 1
Dimensions, Weight: approx. 300(W)× 130(D)× 240(H) mm, 4kg


VA-24VSAutosamplers and Vaporizers
model VA-236S

Automatic and consecutive measurements up to 33 samples(Vials).Carrier gas is controlled by a mass flow controller, realizing a stable flow rate regardless of the gas pressure.
Platics, rubbers, food products, medical products, inorganic salts, powders, and other solid samples can be measured. Certain oil samples can also be measured using a special needle.

Heating temperature: 70~300oC
Gas flow: 0 to 500ml/min(set from moisture meter)
Carrier gas: Nitrogen gas, <0.01 % moisture
Carrier control: Mass flow controller
Vials(10ml): Total 36, including purge vials
Sample size: <10g and < 2.5ml in volume(solids) < 5ml(oils)
Power supply: AC 100-120V, 200VA/AC220-240V, 250VA
Dimensions: 370(W)*560(D)*400(H) mm
Weight: 18kg


Autosamplers and Vaporizers
model VG-200
VA-122
Ideal injector for propane, butane, and other liquefied gases. A predefined amount of LPG will be vaporized and injected into the moisture meter.

Applicable gases: Propane. Butane,other liquefide gases(Up to 5 different gas factors can be set)
Injection rate: 100 to 600ml/min
Injection volume: 1 to 99L
Heater temperature: 40 to 90¢J
Power supply: AC100-120V, 40VA/ AC220-240V, 20VA
Dimensions: 150(W)*350(D)*270(H) mm
Weight: 6 kg


High Temperatures VA-121
model VA-121

Iron ore, clay, metal oxides, inorganic salts

Heating temperature: 250~300oC
Heater: Electric Furnace (Kanthal wire) 800W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
¡@¡@¡@¡@¡@Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 420(W)× 260(D)× 240(H) mm, 15.5kg


High/Low Temperatures VA-122
model VA-122

Enables measurement of ancillary moisture. Iron ore, clay, welding rods, metal oxides, inorganic salts

Heating temperature: 70~300oC, 250~1000oC
Heater: Electric Furnace (Kanthal wire) 1000W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 5ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
¡@¡@¡@¡@¡@Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 690(W)× 290(D)× 410(H) mm, 20kg


Additional Power Supply Unit Additional Power Supply Unit
model CAEPWA

Dimensions: approx. 310(W)× 170(D)× 150(H) mm
Weight: approx. 3kg


VA-210Liquid Dispenser and Disposal Unit CAESD
model CAESD

Dimensions, Weight: approx. 90(W)× 120(D)× 80(H) mm, 708kg
¡°can be used for Cuolometric(fritless), and Volumetric

 

 


 
¡@