Language¡G
¤½¥q²¤¶ ²£«~¤¶²Ð ³Ì·s®ø®§ ³Ì·s²£«~ «P¾P²£«~ ¼tµP¤¶²Ð ÀɮפU¸ü ³sµ¸§Ú­Ì ¦^­º­¶



¹q¸Ñ¦¡¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡½¤«p­p--¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
½¤«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h­«Âì«p«×¤Î¹q¦ì®t´ú©w²Õ¦X-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h¼hÂì¹qÁá­@»G»k´ú©w¸Ë¸m-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡¹qÁá«p«×´ú©w¾¹¥Î ¹q¸Ñ²G-¤¤¥¡»s§@©Ò
¶W­µªi²M¬~¾÷-¤¤¥¡»s§@©Ò
µL¹q¸ÑÂì¹qÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q·½¸Ë¸m/¾ã¬y¾¹-¤¤¥¡»s§@©Ò
¥ú¿A¾¯¦Û°Ê²K¥[¸Ë¸m-¤¤¥¡»s§@©Ò
PH/ORP±±»s¾¹-¤¤¥¡»s§@©Ò
¤T»ù»ÌÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q¸Ñ¤òÃä¥h°£¸Ë¸m-¤¤¥¡»s§@©Ò
ºÏ©Ê/«DºÏ©Ê/¨â¥Î«¬½¤«p­p
¶W­µªi¦h¼h½¤«p­p
X-ray¿Ã¥úÁá¼h´ú«p»ö
ÆQ¤ô¼QÃú¸ÕÅç¾÷
¥iµ{¦¡ùÚ·ÅùÚÀã¸ÕÅç¾÷
ºë±K¯M½c
Thickness Tester-Chuo Seisakusho.,LTD.
ùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù
¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u
¦Û°Êºw©w»ö-¤éªFºë¤u
Á`²¸¤ÀªR»ö-¤éªFºë¤u
Á`´â¤ÀªR»ö-¤éªFºë¤u
Á`´á¤ÀªR»ö-¤éªFºë¤u
¦Û°Ê¼Ë«~¿U¿N¸Ë¸m-¤éªFºë¤u
Á`¦³¾÷³¿¯À¤ÀªR»ö-¤éªFºë¤u
°ª/§Cªý§Ü²v­p-¤éªFºë¤u
¿n¤À²y¦¡¿B«×­p-¤éªFºë¤u
¤ô¥÷­p¥Î¹q¸Ñ²G¤Î¸Õ¾¯-¤éªFºë¤u
Á`¦³¾÷ºÒ¤ÀªR»ö-¤éªFºë¤u
³¿¯À¿O¤ô¥÷­p
¼ö¤ÀªR¨t¦C
¼ö¶Ç¾É«Y¼Æ¨t¦C
  ¤ÀÃþ >>  Á`¦³¾÷ºÒ¤ÀªR»ö-¤éªFºë¤u >> 
    ¦PÃþ°Ó«~ >> 
TOC-300V  Á`¦³¾÷ºÒ¤ÀªR»ö ¤H®ð«ü¼Æ 5504
«¬¸¹¡GTOC-300V
¤¤¤å¦WºÙ¡GÁ`¦³¾÷ºÒ¤ÀªR»ö
­^¤å¦WºÙ¡GTotal Organic Cargon Analyzer
¼tµP¡G¤éªFºë¤u¤ÀªR¬ì§Þ
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³­­¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z

°Ó «~ »¡ ©ú ¸ê ®Æ

 

 
 °Ó«~³W®æ
°Ó«~¦WºÙ¡G

Á`¦³¾÷ºÒ¤ÀªR»öTOC-300V«¬
Total Organic Carbon Analyzer

¡@
 ¿ïÁÊ«~

 Nitrogen Detector ND-210

   

 

¡@

 TOC-300V

Are your current TOC analyzers giving you the TRUE results?

Especially when it comes to samples with high amount of particulates?

We have developed a new TOC analyzer with DIRECT INJECTION METHOD.

This makes our instrument predominantly TOUGH against samples with particulates. Our proficient combustion technology and stable detection technology will also contribute to bring you the TRUE results.

 

Official Test Methods: ISO 8245 (EN1484), EPA 415.1, EPA 9060A, Standard Methods 5310, ASTM D7573

 

 Standard Configuration

Type of Measurement¡G

TOC-300V Total Organic Carbon Analyzer

¡@

 

 

 Option


 

Nitrogen Detector ND-210

   By attaching our well-proven ND-210 (developed of trace nitrogen analysis) to the TOC-300V system, total nitrogen and TOC can be measured simultaneously.

 

Method: Oxidative Combustion/Chemiluminescence Detection (Reduced Pressure Method)

Power: AC 100 to 240V

Dimensions: 220(W)×375×(D)×500(H)mm

Weight: 22kg


 


 

¡@