CA-310 Coulometric ¥d¦¡·L¶q¤ô¥÷p CA-310«¬ (®wÛªk) |
¤H®ð«ü¼Æ |
3774 |
|
|
«¬¸¹¡GCA-310 Coulometric |
¤¤¤å¦WºÙ¡G¥d¦¡·L¶q¤ô¥÷p CA-310«¬ (®wÛªk) |
^¤å¦WºÙ¡GKarl-Fischer Coulometric titration |
¼tµP¡G¤éªFºë¤u¤ÀªR¬ì§Þ |
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z |
|
|
|
|
°Ó «~ »¡ ©ú ¸ê ®Æ |
|
|
°Ó«~³W®æ |
°Ó«~¦WºÙ¡G
|
¥d¦¡·L¶q¤ô¥÷p CA-310«¬ (®wÛªk)
Karl-Fischer Coulometric titration
¡m¥i¥|ÀW¹D¦P®É´ú©w¡B¦P®Éªí¥Ü¡n
|
¯SÂI¡G
|
♦ ÂX¥R¥\¯à»P¦hºØªº·f°tÀ³¥Î¡A³Ì¤j4ÀW¹D¦P®É´ú¶q
♦ IJ±±¦¡±m¦â²G´¹¿Ã¹õ±±¨î
♦ ¥i¥Î©ó¦hºØÀ³¥Î¡A±q²³æªº§å¶q´ú¶q¨ì¥þ¦Û°Ê¤Æ
♦ ¾A¥Î©ó¦hºØ¼sªxªºÀ³¥Î¡AÃÄ«~¡B¹«~¡Bªo«~...µ¥
|
¿Ã¹õ¡G
|
8.4^¦T±m¦â²G´¹Ä²±±¦¡¿Ã¹õ |
«¶q¡G
|
¥D¾÷ CA-310MC: ¬ù 2kg
ÅÍ©Õ®y CA-310STR: ¬ù 2.5kg |
¤Ø¤o¡G
|
¥D¾÷ CA-310MC: ¬ù 245 W× 160 D× 215 Hmm
ÅÍ©Õ®y CA-310STR: ¬ù 120 W× 340 D× 135 Hmm |
|
|
¥d¤ó¤ô¥÷p;¥d¤ó·L¶q¤ô¥÷p;¤ô¥÷p;¤ô¥÷»ö;¤ô¥÷´ú©w»ö;¤ô¤À´ú©w»ö;¤ô¤À¤ÀªR»ö;¤ô¥÷¤ÀªR»ö;¥d¦¡·L¶q¤ô¤Àp;·L¶q¤ô¤À»ö;·L®wÛ¤ô¤À´ú©w¾¹;·L®wÛ¤ô¥÷´ú©w¾¹;¤ÀªR»ö;¤TµÙ¤Æ¾Ç;¤ô¤À´ú©w¾¹;¤TµÙ¤Æ¾Ç¥xÆWÁ`¥N²z;¤ô¥÷´ú©w¾¹;CA-310;Karl-Fischer Moisture Meter;Mitsubishi Chemical Analytech Co Ltd;¥d¤ó¤ô¤Àp;¥d¤ó¤ô¤À»ö;¥d¤ó¤ô¥÷´ú©w»ö;·L¶q¤ô¥÷¤ÀªR»ö;·L¶q¤ô¥÷p;¥d¦¡¤ô¥÷»ö;¤TµÙ¤Æ¾Ç¤ÀªR¬ì§Þ-¥xÆWÁ`¥N²z;¤ô¤Àp¡F¤ô¥÷p¡F¤ô¤À´ú©w¾¹¡F¤ô¥÷´ú©w¾¹¡F¤ô¤À´ú©w»ö¡F¤ô¥÷´ú©w»ö¡F¤ô¤À¤ÀªR»ö¡F¤ô¥÷¤ÀªR»ö¡F¥d¤ó¤ô¤Àp¡F¥d¤ó¤ô¥÷p¡F¥d¦¡¤ô¤Àp¡F¥d¦¡¤ô¥÷p¡F¥d¤ó¤ô¤À»ö¡F¥d¤ó¤ô¥÷»ö¡F¥d¦¡¤ô¤À»ö¡F¥d¦¡¤ô¥÷»ö¡F¥d¤ó¤ô¤À´ú©w»ö¡F¥d¤ó¤ô¥÷´ú©w»ö¡F¥d¦¡¤ô¤À´ú©w»ö¡F¥d¦¡¤ô¥÷´ú©w»ö¡F·L¶q¤ô¤Àp¡F·L¶q¤ô¥÷p¡F·L¶q¤ô¤À¤ÀªR»ö¡F·L¶q¤ô¥÷¤ÀªR»ö¡FKarl Fischer Moisture Titrator¡F
¤°»ò¬O¥dº¸¶O·²º¸ªk¡H
¦p¤U±¤Æ¾Ç¤ÏÀ³¤½¦¡(1)©Ò¥Ü¡A¥dº¸¡E¶O·²º¸ªk¨Ï¥Î¥dº¸¡E¶O·²º¸¸Õ¾¯´ú©w¤ô¤À§t¶q¡A¸Ó¸Õ¾¯©w¶q¦a¡B¦³¿ï¾Ü©Ê¦a»P¤ôµo¥Í¤ÏÀ³¡C¥dº¸¡E¶O·²º¸¸Õ¾¯ªº²Õ¦¨¦¨¤À¬O¸K¡B¤G®ñ¤Æ²¸¡BÆQ°ò©M¾JÃþµ¥·»¾¯¡C
I2 + SO2 + 3 Base + ROH + H2O → 2 Base¡EHI + Base¡EHSO4R…….(1)
¦p¤U©Òz¡A³oºØ¤èªk¥i¥H¥Î©ó®e¶q¤Î®wÛºw©w¨t²Î¡C
¹Ï1¡G
®wÛ´ú©w®wÛºw©w
¥Î®wÛºw©wªkºw©w¡C±N¸Õ¼Ë¥[¤J¹q¸Ñ²G¤¤¡A¨ä¥Dn¦¨¤À¬O¸K¤Æª«Â÷¤l¡B¤G®ñ¤Æ²¸¡BÆQ°ò¥H¤Î¾JÃþµ¥·»¾¯¡C¦p¤½¦¡(2)©Ò¥Ü¡A³q¹L¹q¸Ñ®ñ¤Æ§@¤ë²£¥Í¸K¡Aª½±µ»P¥dº¸¡E¶O·²º¸¸Õ¾¯µo¥Í¤ÏÀ³¡C
2I--2e→I2…….(2)
«ö·Óªk©Ô²Ä©w«ß¡A¸Kªº²£¥Í»P¹q¶q¦¨¥¿¤ñ¡C³o´N·N¨ýµÛ¡A§t¤ô¶q¥i¥H±q¹q¸Ñ®ñ¤Æ©Ò»Ý®wۼƪ½±µ±o¥X¨Ó¡C
1mgªº¤ô=10.71®wÛ
¦p¹Ï1©Ò¥Ü¡A»Ýn¨âºØÃþ«¬ªº®wÛ¸Õ¾¯¡G¤@ºØ¬O¶§·¥¹q¸Ñ²G¡A¸m¹q¸Ñ¼Ñªº¶§·¥«Ç¤¤¡A¥t¥~¤@ºØ¬O³±·¥¹q¸Ñ²G¡A¸m©ó¹q¸Ñ¼Ñªº³±·¥«Ç¤¤¡C®wÛ¸Õ¾¯¤£»Ýn¼Ð©w¡C¥t¤@ÓÀuÂI¬O¥i¥H¤Ï½Æ¨Ï¥Î¡C
®e¿nºw©w®e¶qºw©w
¦b¤@Ó¿N¤¤©ñ¤J¾A¦X©ó¸Õ¼Ëªº²æ¤ô·»¾¯¡C¥Îºw©w¾¯±q¸Ó·»¾¯¤¤Âಾ©Ò¦³ªº¤ô¤À¡CµM«á¡A¥[¤J¸Õ¼Ë¡C¥Îºw©w¾¯¶i¦æºw©w¡Aºw©w¶q(mgH2O/mL)¬O¨Æ¥ý¥Í½T©wªº¡C¸Õ¼Ëªº¤ô¤À§t¶q¥Ñºw©w®e¶q(mL)½T©wªº¡C¨Ï¥ÎùÚ©w¹q¬y·¥¤Æ¹qÀ£ªkÀË´ú²×ÂI¡C¹Ï2Åã¥Ü¤F¨å«¬ªº¦b¥«³õ¤W¾P°âªº¦Û°Ê®e¿nºw©w¨t²Îªº¦UÓ²Õ¦¨³¡¤À¡C
AQUAMICRON®¬O¤TµÙ¤Æ¾Ç®è¦¡·|ªÀµù¥U°Ó¼Ð¡C
“¤éªFºë¤u¤ÀªR¬ì§Þ(«e¨¬°¤TµÙ¤Æ¾Ç)¶°¹Îªº¤l¤½¥qAPI¤½¥q”©ó2002¦~10¤ë¶}©l¦¨¤O¦a¶}®iKF(¥dº¸¡E¶O·²º¸)¸Õ¾¯·~°È¡C¦V«È¤á´£¨Ñ©Ê¯à¨ô¶Vªº¸Õ¾¯¡BªA°È©M§Þ³N¤ä´©¡A¥O«È¤áº¡·N¡C
KF(¥dº¸¡E¶O·²º¸)¸Õ¾¯-AQUAMICRON¦b¤TµÙ¤Æ¾Çªº³À®q¤u¼t¥Í¼t¡A¤u¼tªº½è¶q¨t²Î¹F¨ìISO 9001ªºn¨D¡A¨Ã±o¨ì¤F²Ä¤T¤è»{ÃÒ¡C
|
¡@ |
|
CA-310¡mCoulometric¡n |
Highly scalable with maximum 4-channel simultaneous measurement controlled by wide color touch screen.
The system can be applied for a multiude of applications, from simple batch measurement to full automation.
Progressive moisture meter, CA-310 is active in wide range of applications, pharmaceuticlas, foods, oils etc.
|
|
CA-310 Specifications ¡mCoulometric Moisture Meter¡n |
|
Measurement method:
|
Coulometric Karl-Fischer titration,
4-channel simultaneous measurement (option) |
|
Titration control: |
Constant Current pulse timer control |
|
End point detection: |
Constant current polarization potential |
Electrolysis current: |
430mA (fast dehydration mode 516mA) |
|
Titration speed: |
Avg. 2.2mgH2O /min (36μgH2O/sec.) |
|
Background: |
Automatic correction, constant display,
background level at start of measurement is displayed |
|
Measuring range: |
5μg - 999.9999mg H2O
(5μg measurement: under dry atmosphere) |
|
Detection sensitivity: |
0.1μg H2O |
|
Accuracy: |
<0.3% RSD at 1mg or more H2O |
|
Stirring method: |
Magnetic stirrer |
|
Titration cell: |
Closed, Capacity 150mL |
|
Display: |
8.4 inch color LCD Touch screen |
|
File memory: |
Sample parameters: 99
Schedules: 99
Results: 9,999 |
|
Calculation functions: |
Concentration calculation, statistical calculation,
recalculation, reanalysis of titration curve |
|
Printer: |
Option, thermal or dot impact |
|
Vaporizer operating
functions: |
VA-300, VA-200, VA-210, VA-230, VA-236S, VA-121, VA-122, VG-200
(stepped temperature control available for each vaporizer) |
|
External I/O: |
Electronic balance: Automatic input of weight
USB: 4 ports
LAN: 1 port |
|
Additional functions: |
Data Integrity (GLP/GMP compliance), detection
electrode conditioning |
|
Operating conditions: |
Temperature: 15-40oC
Relative humidity: below 85% (without condensation) |
|
Dimensions, Weight: |
Main Unit: Approx. 245(W)× 160(D)× 215(H) mm, 2kg
Stirrer: Approx. 120(W)× 340(D)× 135(H) mm, 2.5kg |
|
|
Options |
|
Sample Boat Type
model VA-300
Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples
Heating temperature: 50~300oC
Heater: Transparent electro-conductive glass 150W
Sample size: Up to 10g
Measuring range: From 5ppm (when used in combination with CA-300)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Dimensions, Weight: approx. 323(W)× 170(D)× 260(H) mm, 4kg
|
|
Disposable Vial Type
model VA-230
Enables easy measurement using disposable vials. Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples
Heating temperature: 70~300oC
Heater: Aluminum block heater 60W×2
Sample size: Up to 10g and 2.5ml volume, vial volume:10ml
Measuring range: From 30ppm (when used in combination with CA-200)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Gas dryer: Desiccant (Sicapent®) tube, 1
Dimensions, Weight: approx. 300(W)× 135(D)× 220(H) mm, 3.5kg
|
|
Autosamplers and Vaporizers
model VA-236S
Automatic and consecutive measurements up to 33 samples(Vials).Carrier gas is controlled by a mass flow controller, realizing a stable flow rate regardless of the gas pressure.
Platics, rubbers, food products, medical products, inorganic salts, powders, and other solid samples can be measured. Certain oil samples can also be measured using a special needle.
Heating temperature: 70~300oC
Gas flow: 0 to 500ml/min(set from moisture meter)
Carrier gas: Nitrogen gas, <0.01 % moisture
Carrier control: Mass flow controller
Vials(10ml): Total 36, including purge vials
Sample size: <10g and < 2.5ml in volume(solids) < 5ml(oils)
Power supply: AC 100-120V, 200VA/AC220-240V, 250VA
Dimensions: 370(W)*560(D)*400(H) mm
Weight: 18kg
|
|
Autosamplers and Vaporizers
model VG-200
Ideal injector for propane, butane, and other liquefied gases. A predefined amount of LPG will be vaporized and injected into the moisture meter.
Applicable gases: Propane. Butane,other liquefide gases(Up to 5 different gas factors can be set)
Injection rate: 100 to 600ml/min
Injection volume: 1 to 99L
Heater temperature: 40 to 90¢J
Power supply: AC100-120V, 40VA/ AC220-240V, 20VA
Dimensions: 150(W)*350(D)*270(H) mm
Weight: 6 kg
|
|
High Temperatures
model VA-121
Iron ore, clay, metal oxides, inorganic salts
Heating temperature: 250~1000oC
Heater: Electric Furnace (Kanthal wire) 800W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
¡@¡@¡@¡@¡@Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 420(W)× 260(D)× 420(H) mm, 15.5kg
|
|
High/Low Temperatures
model VA-122
Enables measurement of ancillary moisture. Iron ore, clay, welding rods, metal oxides, inorganic salts
Heating temperature: 70~300oC, 250~1000oC
Heater: Electric Furnace (Kanthal wire) 1000W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
¡@¡@¡@¡@¡@Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 690(W)× 290(D)× 410(H) mm, 20kg
|
|
|
¡@ |
°Ó «~ ¨ä ¥¦ ³Æ µù |
|
|
|