Language¡G
¤½¥q²¤¶ ²£«~¤¶²Ð ³Ì·s®ø®§ ³Ì·s²£«~ «P¾P²£«~ ¼tµP¤¶²Ð ÀɮפU¸ü ³sµ¸§Ú­Ì ¦^­º­¶



¹q¸Ñ¦¡¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡½¤«p­p--¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
½¤«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h­«Âì«p«×¤Î¹q¦ì®t´ú©w²Õ¦X-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h¼hÂì¹qÁá­@»G»k´ú©w¸Ë¸m-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡¹qÁá«p«×´ú©w¾¹¥Î ¹q¸Ñ²G-¤¤¥¡»s§@©Ò
¶W­µªi²M¬~¾÷-¤¤¥¡»s§@©Ò
µL¹q¸ÑÂì¹qÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q·½¸Ë¸m/¾ã¬y¾¹-¤¤¥¡»s§@©Ò
¥ú¿A¾¯¦Û°Ê²K¥[¸Ë¸m-¤¤¥¡»s§@©Ò
PH/ORP±±»s¾¹-¤¤¥¡»s§@©Ò
¤T»ù»ÌÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q¸Ñ¤òÃä¥h°£¸Ë¸m-¤¤¥¡»s§@©Ò
ºÏ©Ê/«DºÏ©Ê/¨â¥Î«¬½¤«p­p
¶W­µªi¦h¼h½¤«p­p
X-ray¿Ã¥úÁá¼h´ú«p»ö
ÆQ¤ô¼QÃú¸ÕÅç¾÷
¥iµ{¦¡ùÚ·ÅùÚÀã¸ÕÅç¾÷
ºë±K¯M½c
Thickness Tester-Chuo Seisakusho.,LTD.
ùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù
¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u
¦Û°Êºw©w»ö-¤éªFºë¤u
Á`²¸¤ÀªR»ö-¤éªFºë¤u
Á`´â¤ÀªR»ö-¤éªFºë¤u
Á`´á¤ÀªR»ö-¤éªFºë¤u
¦Û°Ê¼Ë«~¿U¿N¸Ë¸m-¤éªFºë¤u
Á`¦³¾÷³¿¯À¤ÀªR»ö-¤éªFºë¤u
°ª/§Cªý§Ü²v­p-¤éªFºë¤u
¿n¤À²y¦¡¿B«×­p-¤éªFºë¤u
¤ô¥÷­p¥Î¹q¸Ñ²G¤Î¸Õ¾¯-¤éªFºë¤u
Á`¦³¾÷ºÒ¤ÀªR»ö-¤éªFºë¤u
³¿¯À¿O¤ô¥÷­p
¼ö¤ÀªR¨t¦C
¼ö¶Ç¾É«Y¼Æ¨t¦C
  ¤ÀÃþ >>  ¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u >> ¥d¦¡·L¶q¤ô¥÷­p CA-310«¬ (®w­Ûªk) >> 
    ¦PÃþ°Ó«~ >> 
CA-310 Coulometric  ¥d¦¡·L¶q¤ô¥÷­p CA-310«¬ (®w­Ûªk) ¤H®ð«ü¼Æ 3774
«¬¸¹¡GCA-310 Coulometric
¤¤¤å¦WºÙ¡G¥d¦¡·L¶q¤ô¥÷­p CA-310«¬ (®w­Ûªk)
­^¤å¦WºÙ¡GKarl-Fischer Coulometric titration
¼tµP¡G¤éªFºë¤u¤ÀªR¬ì§Þ
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³­­¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z

°Ó «~ »¡ ©ú ¸ê ®Æ

¥d¦¡¤ô¥÷­p CA-200

°Ó«~³W®æ

°Ó«~¦WºÙ¡G

¥d¦¡·L¶q¤ô¥÷­p CA-310«¬ (®w­Ûªk)
Karl-Fischer Coulometric titration
¡m¥i¥|ÀW¹D¦P®É´ú©w¡B¦P®Éªí¥Ü¡n

¯SÂI¡G

♦ ÂX¥R¥\¯à»P¦hºØªº·f°tÀ³¥Î¡A³Ì¤j4ÀW¹D¦P®É´ú¶q
♦ Ä²±±¦¡±m¦â²G´¹¿Ã¹õ±±¨î
♦ ¥i¥Î©ó¦hºØÀ³¥Î¡A±q²³æªº§å¶q´ú¶q¨ì¥þ¦Û°Ê¤Æ
♦ ¾A¥Î©ó¦hºØ¼sªxªºÀ³¥Î¡AÃÄ«~¡B­¹«~¡Bªo«~...µ¥

¿Ã¹õ¡G
8.4­^¦T±m¦â²G´¹Ä²±±¦¡¿Ã¹õ
­«¶q¡G
¥D¾÷     CA-310MC: ¬ù 2kg
ÅÍ©Õ®y  CA-310STR: ¬ù 2.5kg
¤Ø¤o¡G
¥D¾÷     CA-310MC: ¬ù 245 W× 160 D× 215 Hmm
ÅÍ©Õ®y  CA-310STR: ¬ù 120 W× 340 D× 135 Hmm
 
 
½Ð¿ï¥Î¤TµÙ¤ô¥÷»ö±M¥Î¤§ ¶§³±·¥²G¡Bºw©w²G¡B²æ¤ô·»¾¯¤Î¼Ð·Ç«~…µ¥¸Õ¾¯

¿ïÁÊ«~


VA-300
VA-300 ¼Ë«~¦à¥[¼ö»]µo¸Ë¸m
¤Ø¤o¡G¬ù 323W× 170 D× 260 Hmm
­«¶q¡G¬ù 4 kg
¥[¼ö·Å«×¡G50°C¡ã300°C
¸Õ®Æ¶q¡G10g ¥H¤U
´ú©w½d³ò¡G5ppm ¥H¤W
¾A¥Î¼Ë«~¡G¦UºØ¶ì®Æ¡B¾ó½¦¡B­¹«~¡BµL¾÷ÆQÃþ¡BÂåÃÄ«~…µ¥¯»¥½/©TÅé¼Ë¥»

VA-230
VA-230¼Ë«~²~¥[¼ö»]µo¸Ë¸m
¤Ø¤o¡G¬ù 300W× 135 D× 220 Hmm
­«¶q¡G¬ù 3.5 kg
¥[¼ö·Å«×¡G70°C¡ã300°C
¸Õ®Æ¶q¡G10g ©Î 2.5ml ¥H¤U(10ml vials)
´ú©w½d³ò¡G30ppm ¥H¤W ®w­Ûªk
¾A¥Î¼Ë«~¡G¦UºØ¶ì®Æ¡B¾ó½¦¡B­¹«~¡BµL¾÷ÆQÃþ¡BÂåÃÄ«~…µ¥¯»¥½/©TÅé¼Ë¥»

VA-24VS
VA-236S¦Û°Ê¼Ë«~²~¥[¼ö»]µo¸Ë¸m(¦hÀËÅé)
¤Ø¤o¡G¬ù 370W× 560 D× 400 Hmm
­«¶q¡G¬ù 18 kg
¥[¼ö·Å«×¡G70¡ã300°C
¸Õ®Æ¶q¡G¡G<10g and <2.5ml in volume (solids) <5ml (oils)
Vials (10ml)¡GTotal 33, including purge vials
¾A¥Î¼Ë«~¡G¥i³sÄòÀË´ú33ºØ¼Ë«~¡A¡]¤@¯ë©TÅé¥Î¡^¦UºØ¶ì®Æ¡B¾ó½¦¡B­¹«~¡BµL¾÷ÆQÃþ¡BÂåÃÄ«~…µ¥¯»¥½/©TÅé¼Ë¥»¡C

VA-121
VA-121°ª·Å¦¡¥[¼ö»]¼ö¸Ë¸m
¤Ø¤o¡G¬ù 420W× 260 D× 420 Hmm
­«¶q¡G¬ù 15.5 kg
¥[¼ö·Å«×¡G250°C¡ã1000°C
¸Õ®Æ¶q¡G10g ¥H¤U
´ú©w½d³ò¡G10ppm ¥H¤W (CA-310)
¾A¥Î¼Ë«~¡G(°ª·Å¥Î)ÅKÄq¡BÂH¤g¡Bª÷ÄÝ®ñ¤Æª«¤ÎµL¾÷ÆQÃþ…

VA-122
VA-122°ª/§C·ÅÂùÄl¦¡¥[¼ö»]¼ö¸Ë¸m
¤Ø¤o¡G¬ù690W× 290 D× 410 Hmm
­«¶q¡G¬ù20 kg
¥[¼ö·Å«×¡G70°C¡ã300°C, 250~1000°C
¸Õ®Æ¶q¡G10g ¥H¤U
´ú©w½d³ò¡G10ppm ¥H¤W
¾A¥Î¼Ë«~¡GÅKÄq¡BÂH¤g¡B²k±ì¡Bª÷ÄÝ®ñ¤Æª«¤ÎµL¾÷ÆQÃþ…

VA-122
VG-200²G¤Æ®ðÅé®ð¤Æ¸Ë¸m
¤Ø¤o¡G¬ù150W× 350 D× 270 Hmm
­«¶q¡G¬ù 6 kg
¥[¼ö·Å«×¡G40°C¡ã90°C
Injection rate:100 to 600ml/min
Injection volume:1 to 99L
Ideal infector for propane, butane, and other liquefied gases. A predefined amount of LPG will be vaporized and injected into the moisture meter.

 

 

¥d¤ó¤ô¥÷­p;¥d¤ó·L¶q¤ô¥÷­p;¤ô¥÷­p;¤ô¥÷»ö;¤ô¥÷´ú©w»ö;¤ô¤À´ú©w»ö;¤ô¤À¤ÀªR»ö;¤ô¥÷¤ÀªR»ö;¥d¦¡·L¶q¤ô¤À­p;·L¶q¤ô¤À»ö;·L®w­Û¤ô¤À´ú©w¾¹;·L®w­Û¤ô¥÷´ú©w¾¹;¤ÀªR»ö;¤TµÙ¤Æ¾Ç;¤ô¤À´ú©w¾¹;¤TµÙ¤Æ¾Ç¥xÆWÁ`¥N²z;¤ô¥÷´ú©w¾¹;CA-310;Karl-Fischer Moisture Meter;Mitsubishi Chemical Analytech Co Ltd;¥d¤ó¤ô¤À­p;¥d¤ó¤ô¤À»ö;¥d¤ó¤ô¥÷´ú©w»ö;·L¶q¤ô¥÷¤ÀªR»ö;·L¶q¤ô¥÷­p;¥d¦¡¤ô¥÷»ö;¤TµÙ¤Æ¾Ç¤ÀªR¬ì§Þ-¥xÆWÁ`¥N²z;¤ô¤À­p¡F¤ô¥÷­p¡F¤ô¤À´ú©w¾¹¡F¤ô¥÷´ú©w¾¹¡F¤ô¤À´ú©w»ö¡F¤ô¥÷´ú©w»ö¡F¤ô¤À¤ÀªR»ö¡F¤ô¥÷¤ÀªR»ö¡F¥d¤ó¤ô¤À­p¡F¥d¤ó¤ô¥÷­p¡F¥d¦¡¤ô¤À­p¡F¥d¦¡¤ô¥÷­p¡F¥d¤ó¤ô¤À»ö¡F¥d¤ó¤ô¥÷»ö¡F¥d¦¡¤ô¤À»ö¡F¥d¦¡¤ô¥÷»ö¡F¥d¤ó¤ô¤À´ú©w»ö¡F¥d¤ó¤ô¥÷´ú©w»ö¡F¥d¦¡¤ô¤À´ú©w»ö¡F¥d¦¡¤ô¥÷´ú©w»ö¡F·L¶q¤ô¤À­p¡F·L¶q¤ô¥÷­p¡F·L¶q¤ô¤À¤ÀªR»ö¡F·L¶q¤ô¥÷¤ÀªR»ö¡FKarl Fischer Moisture Titrator¡F

 


¤°»ò¬O¥dº¸¶O·²º¸ªk¡H
¦p¤U­±¤Æ¾Ç¤ÏÀ³¤½¦¡(1)©Ò¥Ü¡A¥dº¸¡E¶O·²º¸ªk¨Ï¥Î¥dº¸¡E¶O·²º¸¸Õ¾¯´ú©w¤ô¤À§t¶q¡A¸Ó¸Õ¾¯©w¶q¦a¡B¦³¿ï¾Ü©Ê¦a»P¤ôµo¥Í¤ÏÀ³¡C¥dº¸¡E¶O·²º¸¸Õ¾¯ªº²Õ¦¨¦¨¤À¬O¸K¡B¤G®ñ¤Æ²¸¡BÆQ°ò©M¾JÃþµ¥·»¾¯¡C
I2 + SO2 + 3 Base + ROH + H2O → 2 Base¡EHI + Base¡EHSO4R…….(1)
¦p¤U©Ò­z¡A³oºØ¤èªk¥i¥H¥Î©ó®e¶q¤Î®w­Ûºw©w¨t²Î¡C
¹Ï1¡G

®w­Û´ú©w®w­Ûºw©w
¥Î®w­Ûºw©wªkºw©w¡C±N¸Õ¼Ë¥[¤J¹q¸Ñ²G¤¤¡A¨ä¥D­n¦¨¤À¬O¸K¤Æª«Â÷¤l¡B¤G®ñ¤Æ²¸¡BÆQ°ò¥H¤Î¾JÃþµ¥·»¾¯¡C¦p¤½¦¡(2)©Ò¥Ü¡A³q¹L¹q¸Ñ®ñ¤Æ§@¤ë²£¥Í¸K¡Aª½±µ»P¥dº¸¡E¶O·²º¸¸Õ¾¯µo¥Í¤ÏÀ³¡C
2I--2e→I2…….(2)
«ö·Óªk©Ô²Ä©w«ß¡A¸Kªº²£¥Í»P¹q¶q¦¨¥¿¤ñ¡C³o´N·N¨ýµÛ¡A§t¤ô¶q¥i¥H±q¹q¸Ñ®ñ¤Æ©Ò»Ý®w­Û¼Æª½±µ±o¥X¨Ó¡C
1mgªº¤ô=10.71®w­Û
¦p¹Ï1©Ò¥Ü¡A»Ý­n¨âºØÃþ«¬ªº®w­Û¸Õ¾¯¡G¤@ºØ¬O¶§·¥¹q¸Ñ²G¡A¸m¹q¸Ñ¼Ñªº¶§·¥«Ç¤¤¡A¥t¥~¤@ºØ¬O³±·¥¹q¸Ñ²G¡A¸m©ó¹q¸Ñ¼Ñªº³±·¥«Ç¤¤¡C®w­Û¸Õ¾¯¤£»Ý­n¼Ð©w¡C¥t¤@­ÓÀuÂI¬O¥i¥H¤Ï½Æ¨Ï¥Î¡C

®e¿nºw©w®e¶qºw©w
¦b¤@­Ó¿N¤¤©ñ¤J¾A¦X©ó¸Õ¼Ëªº²æ¤ô·»¾¯¡C¥Îºw©w¾¯±q¸Ó·»¾¯¤¤Âಾ©Ò¦³ªº¤ô¤À¡CµM«á¡A¥[¤J¸Õ¼Ë¡C¥Îºw©w¾¯¶i¦æºw©w¡Aºw©w¶q(mgH2O/mL)¬O¨Æ¥ý¥Í½T©wªº¡C¸Õ¼Ëªº¤ô¤À§t¶q¥Ñºw©w®e¶q(mL)½T©wªº¡C¨Ï¥ÎùÚ©w¹q¬y·¥¤Æ¹qÀ£ªkÀË´ú²×ÂI¡C¹Ï2Åã¥Ü¤F¨å«¬ªº¦b¥«³õ¤W¾P°âªº¦Û°Ê®e¿nºw©w¨t²Îªº¦U­Ó²Õ¦¨³¡¤À¡C

AQUAMICRON®¬O¤TµÙ¤Æ¾Ç®è¦¡·|ªÀµù¥U°Ó¼Ð¡C

“¤éªFºë¤u¤ÀªR¬ì§Þ(«e¨­¬°¤TµÙ¤Æ¾Ç)¶°¹Îªº¤l¤½¥qAPI¤½¥q”©ó2002¦~10¤ë¶}©l¦¨¤O¦a¶}®iKF(¥dº¸¡E¶O·²º¸)¸Õ¾¯·~°È¡C¦V«È¤á´£¨Ñ©Ê¯à¨ô¶Vªº¸Õ¾¯¡BªA°È©M§Þ³N¤ä´©¡A¥O«È¤áº¡·N¡C
KF(¥dº¸¡E¶O·²º¸)¸Õ¾¯-AQUAMICRON¦b¤TµÙ¤Æ¾Çªº³À®q¤u¼t¥Í¼t¡A¤u¼tªº½è¶q¨t²Î¹F¨ìISO 9001ªº­n¨D¡A¨Ã±o¨ì¤F²Ä¤T¤è»{ÃÒ¡C

 

 

¡@

 

CA-310¡mCoulometric¡n

Highly scalable with maximum 4-channel simultaneous measurement controlled by wide color touch screen.
The system can be applied for a multiude of applications, from simple batch measurement to full automation.
Progressive moisture meter, CA-310 is active in wide range of applications, pharmaceuticlas, foods, oils etc.

CA-310

 
 CA-310 Specifications ¡mCoulometric Moisture Meter¡n

Measurement method: 
Coulometric Karl-Fischer titration,
4-channel simultaneous measurement (option)

Titration control:  Constant Current pulse timer control

End point detection:  Constant current polarization potential
Electrolysis current:  430mA (fast dehydration mode 516mA)

Titration speed:  Avg. 2.2mgH2O /min (36μgH2O/sec.)

Background:  Automatic correction, constant display,
background level at start of measurement is displayed

Measuring range:  5μg - 999.9999mg H2O
(5μg measurement: under dry atmosphere)

Detection sensitivity:  0.1μg H2O

Accuracy:  <0.3% RSD at 1mg or more H2O

Stirring method:  Magnetic stirrer

Titration cell:  Closed, Capacity 150mL

Display:  8.4 inch color LCD Touch screen

File memory:  Sample parameters: 99
Schedules: 99
Results: 9,999

Calculation functions:  Concentration calculation, statistical calculation,
recalculation, reanalysis of titration curve

Printer:  Option, thermal or dot impact

Vaporizer operating  
functions: 
VA-300, VA-200, VA-210, VA-230, VA-236S, VA-121, VA-122, VG-200
(stepped temperature control available for each vaporizer)

External I/O:  Electronic balance: Automatic input of weight
USB: 4 ports
LAN: 1 port

Additional functions:  Data Integrity (GLP/GMP compliance), detection
electrode conditioning

Operating conditions:  Temperature: 15-40oC
Relative humidity: below 85% (without  condensation)

Dimensions, Weight:  Main Unit: Approx. 245(W)× 160(D)× 215(H) mm, 2kg
Stirrer: Approx. 120(W)× 340(D)× 135(H) mm, 2.5kg

 
Options

Sample Boat Type VA-300
model VA-300

Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples

Heating temperature: 50~300oC
Heater: Transparent electro-conductive glass 150W
Sample size: Up to 10g
Measuring range: From 5ppm (when used in combination with CA-300)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Dimensions, Weight: approx. 323(W)× 170(D)× 260(H) mm, 4kg


Disposable Vial Type VA-230
model VA-230

Enables easy measurement using disposable vials. Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples

Heating temperature: 70~300oC
Heater: Aluminum block heater 60W×2
Sample size: Up to 10g and 2.5ml volume, vial volume:10ml
Measuring range: From 30ppm (when used in combination with CA-200)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Gas dryer: Desiccant (Sicapent®) tube, 1
Dimensions, Weight: approx. 300(W)× 135(D)× 220(H) mm, 3.5kg


VA-24VSAutosamplers and Vaporizers
model VA-236S

Automatic and consecutive measurements up to 33 samples(Vials).Carrier gas is controlled by a mass flow controller, realizing a stable flow rate regardless of the gas pressure.
Platics, rubbers, food products, medical products, inorganic salts, powders, and other solid samples can be measured. Certain oil samples can also be measured using a special needle.

Heating temperature: 70~300oC
Gas flow: 0 to 500ml/min(set from moisture meter)
Carrier gas: Nitrogen gas, <0.01 % moisture
Carrier control: Mass flow controller
Vials(10ml): Total 36, including purge vials
Sample size: <10g and < 2.5ml in volume(solids) < 5ml(oils)
Power supply: AC 100-120V, 200VA/AC220-240V, 250VA
Dimensions: 370(W)*560(D)*400(H) mm
Weight: 18kg


Autosamplers and Vaporizers
model VG-200
VA-122
Ideal injector for propane, butane, and other liquefied gases. A predefined amount of LPG will be vaporized and injected into the moisture meter.

Applicable gases: Propane. Butane,other liquefide gases(Up to 5 different gas factors can be set)
Injection rate: 100 to 600ml/min
Injection volume: 1 to 99L
Heater temperature: 40 to 90¢J
Power supply: AC100-120V, 40VA/ AC220-240V, 20VA
Dimensions: 150(W)*350(D)*270(H) mm
Weight: 6 kg


High Temperatures VA-121
model VA-121

Iron ore, clay, metal oxides, inorganic salts

Heating temperature: 250~1000oC
Heater: Electric Furnace (Kanthal wire) 800W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
¡@¡@¡@¡@¡@Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 420(W)× 260(D)× 420(H) mm, 15.5kg


High/Low Temperatures VA-122
model VA-122

Enables measurement of ancillary moisture. Iron ore, clay, welding rods, metal oxides, inorganic salts

Heating temperature: 70~300oC, 250~1000oC
Heater: Electric Furnace (Kanthal wire) 1000W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
¡@¡@¡@¡@¡@Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 690(W)× 290(D)× 410(H) mm, 20kg


¡@
°Ó «~ ¨ä ¥¦ ³Æ µù

¦PÃþ°Ó«~ >>
¡¹ ¡@ ¥d¦¡·L¶q¤ô¥÷­p CA-310«¬ (®w­Ûªk) ¡@

40449 ¥x¤¤¥«¥_°Ï¤å©÷ªF¤Gµó173¸¹ Tel:+886-4-2292-2214¡@¡@¡@Fax:+886-4-2292-1341¡@¡@¡@§K¶OªA°È¹q¸Ü¡G0800-286186