CA-310 Volumetric ¥d¦¡·L¶q¤ô¥÷p CA-310«¬ (®e¿nªk) |
¤H®ð«ü¼Æ |
3530 |
|
|
«¬¸¹¡GCA-310 Volumetric |
¤¤¤å¦WºÙ¡G¥d¦¡·L¶q¤ô¥÷p CA-310«¬ (®e¿nªk) |
^¤å¦WºÙ¡GKarl-Fischer Volumetric titration |
¼tµP¡G¤éªFºë¤u¤ÀªR¬ì§Þ |
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z |
|
|
|
|
°Ó «~ »¡ ©ú ¸ê ®Æ |
|
|
°Ó«~³W®æ |
°Ó«~¦WºÙ¡G
|
¥d¦¡·L¶q¤ô¥÷p CA-310«¬ (®e¿nªk)
Karl-Fischer Volumetric titration
¡m¥i¥|ÀW¹D¦P®É´ú©w¡B¦P®Éªí¥Ü¡n
|
¯SÂI¡G
|
♦ ÂX¥R¥\¯à»P¦hºØªº·f°tÀ³¥Î¡A³Ì¤j4ÀW¹D¦P®É´ú¶q
♦ IJ±±¦¡±m¦â²G´¹¿Ã¹õ±±¨î
♦ ¥i¥Î©ó¦hºØÀ³¥Î¡A±q²³æªº§å¶q´ú¶q¨ì¥þ¦Û°Ê¤Æ
♦ ¾A¥Î©ó¦hºØ¼sªxªºÀ³¥Î¡AÃÄ«~¡B¹«~¡Bªo«~...µ¥
|
¿Ã¹õ¡G
|
8.4^¦T±m¦â²G´¹Ä²±±¦¡¿Ã¹õ |
«¶q¡G
|
¥D¾÷ CA-310MC: ¬ù 2kg
ÅÍ©Õ®y CA-310STR: ¬ù 2.5kg
Burette CA-310BRT:¬ù 3.5kg |
¤Ø¤o¡G
|
¥D¾÷ CA-310MC: ¬ù 245 W× 160 D× 215 Hmm
ÅÍ©Õ®y CA-310STR: ¬ù 120 W× 340 D× 135 Hmm
Burette CA-310BRT:¬ù 110 W× 320 D× 275 Hmm |
|
|
¥d¤ó¤ô¥÷p;¥d¤ó·L¶q¤ô¥÷p;¤ô¥÷p;¤ô¥÷»ö;¤ô¥÷´ú©w»ö;¤ô¤À´ú©w»ö;¤ô¤À¤ÀªR»ö;¤ô¥÷¤ÀªR»ö;¥d¦¡·L¶q¤ô¤Àp;·L¶q¤ô¤À»ö;·L®wÛ¤ô¤À´ú©w¾¹;·L®wÛ¤ô¥÷´ú©w¾¹;¤ÀªR»ö;¤TµÙ¤Æ¾Ç;¤ô¤À´ú©w¾¹;¤TµÙ¤Æ¾Ç¥xÆWÁ`¥N²z;¤ô¥÷´ú©w¾¹;CA-310;Karl-Fischer Moisture Meter;Mitsubishi Chemical Analytech Co Ltd;¥d¤ó¤ô¤Àp;¥d¤ó¤ô¤À»ö;¥d¤ó¤ô¥÷´ú©w»ö;·L¶q¤ô¥÷¤ÀªR»ö;·L¶q¤ô¥÷p;¥d¦¡¤ô¥÷»ö;¤TµÙ¤Æ¾Ç¤ÀªR¬ì§Þ-¥xÆWÁ`¥N²z;¤ô¤Àp¡F¤ô¥÷p¡F¤ô¤À´ú©w¾¹¡F¤ô¥÷´ú©w¾¹¡F¤ô¤À´ú©w»ö¡F¤ô¥÷´ú©w»ö¡F¤ô¤À¤ÀªR»ö¡F¤ô¥÷¤ÀªR»ö¡F¥d¤ó¤ô¤Àp¡F¥d¤ó¤ô¥÷p¡F¥d¦¡¤ô¤Àp¡F¥d¦¡¤ô¥÷p¡F¥d¤ó¤ô¤À»ö¡F¥d¤ó¤ô¥÷»ö¡F¥d¦¡¤ô¤À»ö¡F¥d¦¡¤ô¥÷»ö¡F¥d¤ó¤ô¤À´ú©w»ö¡F¥d¤ó¤ô¥÷´ú©w»ö¡F¥d¦¡¤ô¤À´ú©w»ö¡F¥d¦¡¤ô¥÷´ú©w»ö¡F·L¶q¤ô¤Àp¡F·L¶q¤ô¥÷p¡F·L¶q¤ô¤À¤ÀªR»ö¡F·L¶q¤ô¥÷¤ÀªR»ö¡FKarl Fischer Moisture Titrator¡F
¤°»ò¬O¥dº¸¶O·²º¸ªk¡H
¦p¤U±¤Æ¾Ç¤ÏÀ³¤½¦¡(1)©Ò¥Ü¡A¥dº¸¡E¶O·²º¸ªk¨Ï¥Î¥dº¸¡E¶O·²º¸¸Õ¾¯´ú©w¤ô¤À§t¶q¡A¸Ó¸Õ¾¯©w¶q¦a¡B¦³¿ï¾Ü©Ê¦a»P¤ôµo¥Í¤ÏÀ³¡C¥dº¸¡E¶O·²º¸¸Õ¾¯ªº²Õ¦¨¦¨¤À¬O¸K¡B¤G®ñ¤Æ²¸¡BÆQ°ò©M¾JÃþµ¥·»¾¯¡C
I2 + SO2 + 3 Base + ROH + H2O → 2 Base¡EHI + Base¡EHSO4R…….(1)
¦p¤U©Òz¡A³oºØ¤èªk¥i¥H¥Î©ó®e¶q¤Î®wÛºw©w¨t²Î¡C
¹Ï1¡G
®wÛ´ú©w®wÛºw©w
¥Î®wÛºw©wªkºw©w¡C±N¸Õ¼Ë¥[¤J¹q¸Ñ²G¤¤¡A¨ä¥Dn¦¨¤À¬O¸K¤Æª«Â÷¤l¡B¤G®ñ¤Æ²¸¡BÆQ°ò¥H¤Î¾JÃþµ¥·»¾¯¡C¦p¤½¦¡(2)©Ò¥Ü¡A³q¹L¹q¸Ñ®ñ¤Æ§@¤ë²£¥Í¸K¡Aª½±µ»P¥dº¸¡E¶O·²º¸¸Õ¾¯µo¥Í¤ÏÀ³¡C
2I--2e→I2…….(2)
«ö·Óªk©Ô²Ä©w«ß¡A¸Kªº²£¥Í»P¹q¶q¦¨¥¿¤ñ¡C³o´N·N¨ýµÛ¡A§t¤ô¶q¥i¥H±q¹q¸Ñ®ñ¤Æ©Ò»Ý®wۼƪ½±µ±o¥X¨Ó¡C
1mgªº¤ô=10.71®wÛ
¦p¹Ï1©Ò¥Ü¡A»Ýn¨âºØÃþ«¬ªº®wÛ¸Õ¾¯¡G¤@ºØ¬O¶§·¥¹q¸Ñ²G¡A¸m¹q¸Ñ¼Ñªº¶§·¥«Ç¤¤¡A¥t¥~¤@ºØ¬O³±·¥¹q¸Ñ²G¡A¸m©ó¹q¸Ñ¼Ñªº³±·¥«Ç¤¤¡C®wÛ¸Õ¾¯¤£»Ýn¼Ð©w¡C¥t¤@ÓÀuÂI¬O¥i¥H¤Ï½Æ¨Ï¥Î¡C
®e¿nºw©w®e¶qºw©w
¦b¤@Ó¿N¤¤©ñ¤J¾A¦X©ó¸Õ¼Ëªº²æ¤ô·»¾¯¡C¥Îºw©w¾¯±q¸Ó·»¾¯¤¤Âಾ©Ò¦³ªº¤ô¤À¡CµM«á¡A¥[¤J¸Õ¼Ë¡C¥Îºw©w¾¯¶i¦æºw©w¡Aºw©w¶q(mgH2O/mL)¬O¨Æ¥ý¥Í½T©wªº¡C¸Õ¼Ëªº¤ô¤À§t¶q¥Ñºw©w®e¶q(mL)½T©wªº¡C¨Ï¥ÎùÚ©w¹q¬y·¥¤Æ¹qÀ£ªkÀË´ú²×ÂI¡C¹Ï2Åã¥Ü¤F¨å«¬ªº¦b¥«³õ¤W¾P°âªº¦Û°Ê®e¿nºw©w¨t²Îªº¦UÓ²Õ¦¨³¡¤À¡C
AQUAMICRON®¬O¤TµÙ¤Æ¾Ç®è¦¡·|ªÀµù¥U°Ó¼Ð¡C
“¤éªFºë¤u¤ÀªR¬ì§Þ(«e¨¬°¤TµÙ¤Æ¾Ç)¶°¹Îªº¤l¤½¥qAPI¤½¥q”©ó2002¦~10¤ë¶}©l¦¨¤O¦a¶}®iKF(¥dº¸¡E¶O·²º¸)¸Õ¾¯·~°È¡C¦V«È¤á´£¨Ñ©Ê¯à¨ô¶Vªº¸Õ¾¯¡BªA°È©M§Þ³N¤ä´©¡A¥O«È¤áº¡·N¡C
KF(¥dº¸¡E¶O·²º¸)¸Õ¾¯-AQUAMICRON¦b¤TµÙ¤Æ¾Çªº³À®q¤u¼t¥Í¼t¡A¤u¼tªº½è¶q¨t²Î¹F¨ìISO 9001ªºn¨D¡A¨Ã±o¨ì¤F²Ä¤T¤è»{ÃÒ¡C
|
¡@ |
|
CA-310¡mVolumetric¡n |
Highly scalable with maximum 4-channel simultaneous measurement controlled by wide color touch screen.
The system can be applied for a multiude of applications, from simple batch measurement to full automation.
Progressive moisture meter, CA-310 is active in wide range of applications, pharmaceuticlas, foods, oils etc.
|
|
CA-310 Specifications ¡mVolumetric Moisture Meter¡n
Measurement method: Volumetric Karl-Fischer Titration,
Up to 4-channel simultaneous measurement (optional)
Titration control: Proportional polarization potential comparator
Detection: Constant current polarization potential
Measuring range: 0.1mg - 999.999mg H2O
Stirring method: Magnetic stirrer
Titration flask: Open vessel with lid, Capacity 150mL
Display: 8.4-inch color LCD touch screen
File memory: Sample parameters: 99
Factor parameters: 99
Schedules: 99
Results: 9,999
Calculation: Concentration calculation, statistical calculation,
recalculation, reanalysis of titration curve
Buret: Syringe type
Volume: 10mL (option 25mL)
Dosing speed: 1mL/ 1.5sec
Aspiration speed: 1mL/ 1.5sec
Accuracy: ±0.02mL (10mL syringe)
Printer: Option, thermal or dot impact
External input and output:
Electric balance: Automatic input of weight
USB: 4 ports
LAN: 1 port
Additional functions: Data integrity (GLP/GMP support), detection
electrode conditioning
Bromine mode: Bromine Index and Bromine Number
Operating conditions: Temperature: 15-40oC
Relative humidity: below 85% ; do not condense.
Power supply: AC 100/115/230/240V (50/60 Hz) 80VA
Dimensions: CA-310MC: Approx. 245(W)× 160(D)× 215(H) mm
CA-310STR: Approx. 120(W)× 340(D)× 135(H) mm
CA-310BRT: Approx. 110(W)× 320(D)× 275(H) mm
Weight: CA-310MC: Approx. 2.0kg
CA-310STR: Approx. 2.5kg
CA-310BRT: Approx. 3.5kg
|
|
Options |
|
Sample Boat Type
model VA-300
Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples
Heating temperature: 50~300oC
Heater: Transparent electro-conductive glass 150W
Sample size: Up to 10g
Measuring range: From 5ppm (when used in combination with CA-300)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Dimensions, Weight: approx. 323(W)× 170(D)× 260(H) mm, 4kg
|
|
Disposable Vial Type
model VA-230
Enables easy measurement using disposable vials. Various types of plastics, rubber, foods, pharmaceuticals, inorganic salts and other powders and solid samples
Heating temperature: 70~300oC
Heater: Aluminum block heater 60W×2
Sample size: Up to 10g and 2.5ml volume, vial volume:10ml
Measuring range: From 30ppm (when used in combination with CA-200)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Gas dryer: Desiccant (Sicapent®) tube, 1
Dimensions, Weight: approx. 300(W)× 135(D)× 220(H) mm, 3.5kg
|
|
Autosamplers and Vaporizers
model VA-236S
Automatic and consecutive measurements up to 33 samples(Vials).Carrier gas is controlled by a mass flow controller, realizing a stable flow rate regardless of the gas pressure.
Platics, rubbers, food products, medical products, inorganic salts, powders, and other solid samples can be measured. Certain oil samples can also be measured using a special needle.
Heating temperature: 70~300oC
Gas flow: 0 to 500ml/min(set from moisture meter)
Carrier gas: Nitrogen gas, <0.01 % moisture
Carrier control: Mass flow controller
Vials(10ml): Total 36, including purge vials
Sample size: <10g and < 2.5ml in volume(solids) < 5ml(oils)
Power supply: AC 100-120V, 200VA/AC220-240V, 250VA
Dimensions: 370(W)*560(D)*400(H) mm
Weight: 18kg
|
|
Autosamplers and Vaporizers
model VG-200
Ideal injector for propane, butane, and other liquefied gases. A predefined amount of LPG will be vaporized and injected into the moisture meter.
Applicable gases: Propane. Butane,other liquefide gases(Up to 5 different gas factors can be set)
Injection rate: 100 to 600ml/min
Injection volume: 1 to 99L
Heater temperature: 40 to 90¢J
Power supply: AC100-120V, 40VA/ AC220-240V, 20VA
Dimensions: 150(W)*350(D)*270(H) mm
Weight: 6 kg
|
|
High Temperatures
model VA-121
Iron ore, clay, metal oxides, inorganic salts
Heating temperature: 250~1000oC
Heater: Electric Furnace (Kanthal wire) 800W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
¡@¡@¡@¡@¡@Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 420(W)× 260(D)× 420(H) mm, 15.5kg
|
|
High/Low Temperatures
model VA-122
Enables measurement of ancillary moisture. Iron ore, clay, welding rods, metal oxides, inorganic salts
Heating temperature: 70~300oC, 250~1000oC
Heater: Electric Furnace (Kanthal wire) 1000W
Sample size: Up to 10g (using quartz boat)
Carrier gas Nitrogen gas, 0.1~0.5 l/min
Measuring range: From 10ppm (when used in combination with CA-200)
Gas dryer: Desiccant (Sicapent®) tube, 1
¡@¡@¡@¡@¡@Desiccant (Sicapent®) tube, 2
Dimensions, Weight: approx. 690(W)× 290(D)× 410(H) mm, 20kg
|
|
|
¡@ |
°Ó «~ ¨ä ¥¦ ³Æ µù |
|
|
|