Language¡G
¤½¥q²¤¶ ²£«~¤¶²Ð ³Ì·s®ø®§ ³Ì·s²£«~ «P¾P²£«~ ¼tµP¤¶²Ð ÀɮפU¸ü ³sµ¸§Ú­Ì ¦^­º­¶



¹q¸Ñ¦¡¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡½¤«p­p--¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
½¤«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹qÁὤ«p­p-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h­«Âì«p«×¤Î¹q¦ì®t´ú©w²Õ¦X-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¦h¼hÂì¹qÁá­@»G»k´ú©w¸Ë¸m-¤¤¥¡»s§@©Ò¥xÆWÁ`¥N²z
¹q¸Ñ¦¡¹qÁá«p«×´ú©w¾¹¥Î ¹q¸Ñ²G-¤¤¥¡»s§@©Ò
¶W­µªi²M¬~¾÷-¤¤¥¡»s§@©Ò
µL¹q¸ÑÂì¹qÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q·½¸Ë¸m/¾ã¬y¾¹-¤¤¥¡»s§@©Ò
¥ú¿A¾¯¦Û°Ê²K¥[¸Ë¸m-¤¤¥¡»s§@©Ò
PH/ORP±±»s¾¹-¤¤¥¡»s§@©Ò
¤T»ù»ÌÁá²GºÞ²z¸Ë¸m-¤¤¥¡»s§@©Ò
¹q¸Ñ¤òÃä¥h°£¸Ë¸m-¤¤¥¡»s§@©Ò
ºÏ©Ê/«DºÏ©Ê/¨â¥Î«¬½¤«p­p
¶W­µªi¦h¼h½¤«p­p
X-ray¿Ã¥úÁá¼h´ú«p»ö
ÆQ¤ô¼QÃú¸ÕÅç¾÷
¥iµ{¦¡ùÚ·ÅùÚÀã¸ÕÅç¾÷
ºë±K¯M½c
Thickness Tester-Chuo Seisakusho.,LTD.
ùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù
¥d¦¡·L¶q¤ô¥÷­p-¤éªFºë¤u
¦Û°Êºw©w»ö-¤éªFºë¤u
Á`²¸¤ÀªR»ö-¤éªFºë¤u
Á`´â¤ÀªR»ö-¤éªFºë¤u
Á`´á¤ÀªR»ö-¤éªFºë¤u
¦Û°Ê¼Ë«~¿U¿N¸Ë¸m-¤éªFºë¤u
Á`¦³¾÷³¿¯À¤ÀªR»ö-¤éªFºë¤u
°ª/§Cªý§Ü²v­p-¤éªFºë¤u
¿n¤À²y¦¡¿B«×­p-¤éªFºë¤u
¤ô¥÷­p¥Î¹q¸Ñ²G¤Î¸Õ¾¯-¤éªFºë¤u
Á`¦³¾÷ºÒ¤ÀªR»ö-¤éªFºë¤u
³¿¯À¿O¤ô¥÷­p
¼ö¤ÀªR¨t¦C
¼ö¶Ç¾É«Y¼Æ¨t¦C
  ¤ÀÃþ >>  Á`´á¤ÀªR»ö-¤éªFºë¤u >> Á`´á¤ÀªR»ö TN-110«¬ >> 
    ¦PÃþ°Ó«~ >> 
TN-110  Á`´á¤ÀªR»ö TN-110«¬ ¤H®ð«ü¼Æ 5036
«¬¸¹¡GTN-110
¤¤¤å¦WºÙ¡GÁ`´á¤ÀªR»ö TN-110«¬
­^¤å¦WºÙ¡GTotal Nitrogen Analyzer model TN-110
¼tµP¡G¤éªFºë¤u¤ÀªR¬ì§Þ
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³­­¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z

°Ó «~ »¡ ©ú ¸ê ®Æ

 

TN-110
°Ó«~³W®æ
°Ó«~¦WºÙ¡G

Á`´á¤ÀªR»ö TN-110«¬
Total Nitrogen Analyzer model TN-110
(©TÅé¡B«D¤ô¨t¡B®ðÅé¼Ë«~¤ÀªR)
¡m¤ô¥­Äl¿U¿N¤è¦¡¡n

´ú©w­ì²z¡G
°ª·Å®ñ¤Æµõ¸Ñ¤À¾Çµo¥úªk
¼Ë«~¾É¤J¡G

±Ä¼Ë«~¦à¦Û°Ê±±¨î¾É¤J

¼Ë«~¨ú¶q¡G
©TÅé 1~3mg¡A«D¤ô 5~50ml¡A®ðÅé 1~10ml
´ú¶q½d³ò¡G
·¥·L¶q~5000ppm
´ú©w®É¶¡¡G
3~10¤À
¾Þ§@±±¨î¡G
PC°t¦X³nÅéµ{¦¡Data Base
©Ò»Ý®ðÅé¡G
Ar 99.98%¥H¤W, O2 99.7%¥H¤W
¾A¥Î¹ï¶H¡G

¥Ûªo­ì®Æ©Î¥Û¤Æ»sªo¡BÂH¸Yª«®Æ¡B¾ð¯×ªº¦UºØ©TÅé¤Î«D¤ô¨t¼Ë«~
¨Ò¡GGas Oil, Crude, Lubricating Oil, Polyethylene, Polycarbonate, Polystylene, Polypropylene, Epoxy Resin, Paper, Toner, Uinyl Acetate, Wax...

IJ·Ñ¡G
¥Õª÷®ñ¤ÆIJ´C
²Å¦X¼Ð·Ç¡G

ASTM-D4629, D5176, D5762¤ÎD6069
JIS-K0102¤ÎJIS-K2609…

¡@

 

¿ïÁÊ«~

ASC-150L

ASC-150L (Liquid Auto sampler)

¾A¥Î©ó²GÅé¼Ë¥»

ASC-120S ASC-120S (Solid Auto Sampler)

 


CRI-100H CRI-100H (Constant Rate Injector)

 


GI-100

GI-100 ®ðÅéª`®g¾¹

¾A¥Î©ó®ðÅé¼Ë¥»

¡@
TN-110
Trace amounts of nitrogen can be measured accurately and rapidly in various types of non-aqueous and solid samples including resins and petrochemical products. The use of database software for data processing allows data to be stored and retrieved easily. In addition, options accommodating various types of samples are also useful in analysis.
 
TN-110+ND-100+Auto Boat Controller

System Configuration for Measurement of Non-Aqueous Samples

 

Features
Easy Measurement of Trace Amounts of Nitrogen in solid Samples
The TN-110 demonstrated powerful capabilities in measurement of trace amounts of nitrogen in various types of solid and non-aqueous samples such as resins and petrochemical products. All measurement conditions can be set while viewing the PC display. In addition, the combustion conditions of the Automatic Boat controller (including sample boat introduction position and hold time) can be set while viewing the PC display. This analysis is used in the certified methods indicated below.

Oxidation decomposition and chemiluminescence
JIS-K0102, JIS-K2609,
ASTM-D4629, D5176, D5762 and D6069
System Configuration Corresponding to the Purpose of Use
The system can be configured exactly as required by using various options according to the particular sample.
Outstanding Ease of Operation and Improved Functions Using Windows® 95/98
The system can be operated easily by using a mouse. All measurement conditions are contained in the database, allowing samples to be measured simply by selecting the optimum conditions.
High-Speed Analysis Through the Use of Automatic Boat Controller (ABC)
Operation is started simply by placing a sample in the sample boat. Analysis is performed automatically in about 6-12 minutes. The standard system enables sample analysis to be performed with outstanding reproducibility. Since the sample inlet box is provided with a cooling function (electronic cooling), the sample boat can be cooled in a short time.
 

 


 

 TN-110 Specifications

Samples:  Solid, non-aqueous and gaseous samples*1

Analysis method:  Oxidative pyrolysis-chemiluminescence method

Catalyst:  Platinum oxidation catalyst

Sample introduction  
method: 
Automatically introduced using sample boats
(using automatic boat controller)

Sample size :  Solid samples:1-30mg,
non-aqueous samples:5-50μl*2,
gaseous samles:1-10ml

Furnace  
temperature: 
Max. 1,100oC (sample introduction unit and catalyst unit can be set separately)

Measurement range:  0.5-5,000ppm

Measurement time:  3-10 min./measurement

Gas requirements:  Argon ¡@(purity:99.98% or more, 290-490 kPa)
Oxygen(purity:99.7% or more, 290-490 kPa)

Dimensions, weight:  Main unit: approx. 450(W)×360(D)×430(H)mm, 17kg
ND-100: approx. 260(W)×400(D)×430(H)mm, 17kg
ABC: approx. 440(W)×250(D)×180(H)mm, 11kg

*1 : The optional gas injector (GI-100) is required when measuring gaseous samples.
*2 :The amount of sample injected can be increased up to 200μl by using the optional constant rate injector (CRI-100H) when measuring liquid samples.

 

 
Options

Liquid Auto SamplerASC-150L
model ASC-150L

Liquid samples are measured, injected and rinsed automatically using a micro syringe. Up to 50 sample vials can be placed in the sampler, and 50 samples can be processed automatically, including sampling, measurement, data processing and report generation. Furthermore, this sampler is used in combination with the Automatic Boat Controller provided as standard equipment.
 

Solid Auto Sampler ASC-120S
model ASC-120S

Up to 20 solid samples can be measured automatically. The main unit contains a built-in automatic boat controller, and samples weighed in the quartz boats are measured according to predetermined combustion conditions.

Sample: Solids/ Viscous Liquid Samples
Sample Size: Less than 30mg
Sample Boat: 20 Places
            Quarts Sample boat or Ceramic sample Boat
Sample Introduction: Built-in Automatic Boat controller (ABC)
Stop points: 3 points+ End point+ Cooling Point
Boat cooling: Peltier Cooler
 
 

Constant Rate Injector CRI-100V
model CRI-100H

Liquid samples are injected at a constant rate using a micro syringe. Even samples that burn with difficulty can be measured with high accuracy by controlling the injection rate.

Syringe: 50μl, 100μl, 250μl (gas-tight micro syringes)
Injection rate: 0.4-2.0μl/sec. (sample injection rate is normally 1.0μl/sec.)
Injection volume: 250 μl
 

Gas Injector GI-100
model GI-100

This system is used for analysis of sulfur and nitrogen in gaseous samples.

Applicable samples: Gaseous samples
Standard sample size: Max. 20μl (Gastight Micro syringe)
Gas sample size: Max. 10μl (Gastight Micro syringe)
Gas requirements: Argon (purity:99.98% or more, 290-490kPa)
 

 
¡@