TCL-2100V Á`´â/²¸¤ÀªR»ö TCL-2100V«¬ |
¤H®ð«ü¼Æ |
4386 |
|
|
«¬¸¹¡GTCL-2100V |
¤¤¤å¦WºÙ¡GÁ`´â/²¸¤ÀªR»ö TCL-2100V«¬ |
^¤å¦WºÙ¡GTrace Chlorine/Sulfur Analyzer |
¼tµP¡G¤éªFºë¤u¤ÀªR¬ì§Þ |
¨ÑÀ³°Ó¡Gµ¾¶T»ö¾¹¦³¤½¥q ¤¤¥¡»s§@©Ò ¥xÆWÁ`¥N²z |
|
|
|
|
°Ó «~ »¡ ©ú ¸ê ®Æ |
|
¨ã¦³¤@©wµû»ù¤§ÂÇ®wÛªk¤è¦¡Â²³æ´ú©w²GÅé¡A®ðÅ餤¤§·L¶q®ð¤Î²¸§t¶q¡C
¥Ûªo¤Æ¾Ç¤u¼t¡A¤Æ¾Ç»s³y¼t§÷®Æ»s³y¼tµ¥…¡A¨Ï©Ò¦³¤§²£·~ïH°ì¬¡ÅD¡C
²Å¦X¦p¤U¤§¤½©wªk¡G
CI¡GASTM D5808, JPI 5S-64-02, TS K0010
S ¡GASTM D3120, 3140, JIS K2541, 2240
|
¯S ÂI¡G
|
-
Àu½èµøµ¡¾Þ§@©Ê¡A¥\¯à´£ª@
-
¨t²Î¨ÌÀ³¥Î¥Øªººc¦¨
-
¦Û°Ê¦à±±»s¡A§Ö³t¤ÀªR
-
¤À³ÎÄl³]p¡A«O¾i´£¤É
|
¥K¼Ë
|
|
Á`´â/²¸¤ÀªR»ö TCL-2100V«¬
Trace Chlorine/Sulfur Analyzer
¡m««ª½Äl¿U¿N¤è¦¡¡n
|
|
´â¤ÀªR¸Ë¸m
|
²¸¤ÀªR¸Ë¸m
|
|
²GÅé¤Î®ðÅé¼Ë«~
|
|
®ñ¤Æ¤À¸Ñ¡B¹q¶qºw©w
|
|
®ñ¤ÆÁÙ¤¸¹q¦ì(¥Ñ¹q·¥¤§¹q¦ì®tÀË¥X)
|
|
¶}³¬¦¡¹q®ðÄl¡G¤G¤À³Î¤è¦¡¡B·Å«×³Ì°ª¡G1,100¡C C(¼Ë«~ª`¤J³¡¤Î¤ÏÀ³³¡¥iÓ§O³]©w)
|
|
´â¯À´ú©w¡G»È¹q·¥
|
|
0.01~50μm
³q±`¤§¸Õ®Æ¡G1,000¡C C ¥H¤U¿U¿N¬O¤£§t§«®`¿U¿N¤§¼Ë«~)
|
0.02~20μm
³q±`¤§¸Õ®Æ¡G1,000¡C C ¥H¤U¿U¿N¬O¤£§t§«®`¿U¿N¤§¼Ë«~)
|
|
¨Ì¿ïÁʸ˸m¦Ó²§¡A¨Ì¿ïÁʸ˸m½T©wª`¤J¶q
|
|
10¤À¥H¤º/¥ó(2μg´ú©w®É)*2
|
|
´ã®ð(¯Â«×99.8%¥H¤W¡A200~400kPa)
®ñ®ð(¯Â«×99.7%¥H¤W¡A200~400kPa)
|
|
VF-210 AC100/115/230/240V¡B50/60Hz¡B1,000VA
MCD-210 AC100/115/230//240V¡B50/60Hz¡B150VA
|
|
VF-210 ¬ù500(W)¢®430(D)¢®500(H)mm¡B¬ù35kg
MCD-210 ¬ù220(W)¢®375(D)¢®500(H)mm¡B¬ù14kg
|
|
|
¡@ |
¡@
TCL-2100V
|
New instrument TCL-2100V can measure total chlorine/sulfur from trace level in fast, easy way. It can be applicable to variety of liquid and gaseous samples by approved coulometric analysis.
CI¡GASTM D5808, JPI 5S-64-02, TS K0010
S ¡GASTM D3120, 3140, JIS K2541, 2240
|
Features¡G
|
• Trace chlorine measurement down to 0.05 ppm in Liquid sample.
• Application-oriented system configuration.
• Accurate and stable analysis
• Fully automated running
• Data output for LIMS*
• Energy saving, cut useless electric power consumption and gases.
|
Standard specification
|
|
TCL-2100V
Trace Chlorine/Sulfur Analyzer
|
|
Oxidative decomposition
|
coulometric titration
|
|
liquid, non pressurized gas
|
|
Potential difference by electrodes (oxidation-reduction potential)
|
|
Open-close electric furnace: two parts, max 1100 °C. (Individually controlled for injection and pyrolysis)
|
Detection electrodes ¡G
|
Chlorine: Silver
|
Sulfur: Platinum
|
|
Chlorine: 0.01 − 50 μg (0.05 − 1000ppm)
|
Sulfur: 0.02 − 50 μg (0.1−1000ppm)
|
|
< 10 min at 2 μg*
|
|
Argon: 200 − 400 kPa, > 99.98% purity / Oxigen: 200 − 400 kPa, >99.7% purity
|
|
VF-210; AC 100/115/230/240V, 50/60 Hz, 1000VA
MCD-210; AC 100/115/230/240V, 50/60 Hz, 150VA
|
|
VF-210; Approx. 500(W) x 430(D) x 500(H)mm, Approx. 35kg
MCD-210; Approx. 220(W) x 375(D) x 500(H)mm, Approx. 14kg
|
|
Option
|
|
|
GI-210 (Gas Injector)
Gaseous sample will be injected by gastight syringe manually into inert gas to ensure safety.
|
|
|
ASC-250L (Liquid Auto Sample Changer)
Liquid sample can be measured fully automatically from sampling to injection and rinsing. Microsyringe handles up to 200 μl injection and 50 vials can be placed for complete automation of sampling.
|
|
|
GI-220 (Gas Injector)
Gaseous sample will be injected by syringe pump for
automatic measuring. Injection line can be purged by
next sample for measurement.
|
|
|
|
¡@ |
°Ó «~ ¨ä ¥¦ ³Æ µù |
|
|
|